AI Article Synopsis

  • The MMAA gene is essential for the metabolism of cobalamin (vitamin B12), and mutations in this gene cause a type of disorder known as cblA, which is associated with excessive methylmalonic acid in the urine.
  • A high-resolution melting analysis (HRMA) was developed to quickly identify mutations in the MMAA gene among various patient groups and confirmed variants through Sanger sequencing.
  • The study identified new variants, including ten previously unreported mutations, all of which are predicted to be damaging, highlighting the potential limitations of current diagnostic methods for mild cases of cblA disorders.

Article Abstract

The gene product of MMAA is required for the intracellular metabolism of cobalamin (Cbl). Mutations in this gene lead to the cblA class of disorders, characterized by isolated methylmalonic aciduria. We have been concerned that somatic cell methods of diagnosis may miss patients with mild cellular phenotypes. A high resolution melting analysis (HRMA) assay was developed to rapidly scan the coding exons and flanking intronic regions of the MMAA gene for variants. DNA was scanned by HRMA from 96 unaffected reference individuals, 72 cblA patients confirmed by complementation, and 181 patients with isolated elevated methylmalonic acid, who could not be diagnosed using complementation analysis. Suspected variants were confirmed by Sanger sequencing. In the cblA cohort, HRMA correctly identified all previously known mutations as well as an additional 22 variants, 10 of which had not been previously reported. Novel variants included one duplication (c.551dupG, p.C187LfsX3), one deletion (c.387delC, p.Y129YfsX13), one splice site mutation (c.440-2A>G, splice site), 4 missense mutations (c.748G>A, p.E520K; c.820G>A, p.G274S; c.627G>T, p.R209S; c.826A>G, p.K276E), and 3 nonsense mutations (c.960G>A, p.W320X; c.1075C>T, p.E359X; c.1084C>T, p.Q362X). All novel missense variants affect highly conserved residues and are predicted to be damaging. Scanning of MMAA in the 181 undiagnosed samples revealed a single novel heterozygous missense change (c.821G>A, p.G274D).

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ymgme.2012.09.012DOI Listing

Publication Analysis

Top Keywords

high resolution
8
resolution melting
8
melting analysis
8
mmaa gene
8
methylmalonic aciduria
8
splice site
8
variants
5
mmaa
4
analysis mmaa
4
gene
4

Similar Publications

Background: Computed tomography (CT) is the gold standard imaging modality for the assessment of 3D bony morphology but incurs the cost of ionizing radiation exposure. High-resolution 3D magnetic resonance imaging (MRI) with CT-like bone contrast (CLBC) may provide an alternative to CT in allowing complete evaluation of both bony and soft tissue structures with a single MRI examination.

Purpose: To review the technical aspects of an optimized stack-of-stars 3D gradient recalled echo pulse sequence method (3D-Bone) in generating 3D MR images with CLBC, and to present a pictorial review of the utility of 3D-Bone in the clinical assessment of common musculoskeletal conditions.

View Article and Find Full Text PDF

Centimeter-Sized CsPbBr Single-Crystal Films for Energy-Resolved Radiation Detection.

ACS Appl Mater Interfaces

January 2025

Beijing Key Laboratory of Construction-Tailorable Advanced Functional Materials and Green Applications Experimental Center of Advanced Materials, School of Materials Science and Engineering, Beijing Institute of Technology, Beijing 100081, China.

Metal halide perovskites (MHPs) are promising materials for radiation detection. Compared with polycrystalline films, single crystals (SCs) have lower defect density, higher carrier mobility, and lifetime. However, the direct synthesis of MHP SCs for large-area flat panel imaging detectors remains challenging.

View Article and Find Full Text PDF

Purpose: MR-based FID navigators (FIDnavs) do not require gradient pulses and are attractive for prospective motion correction (PMC) due to short acquisition times and high sampling rates. However, accuracy and precision are limited and depend on a separate calibration measurement. Besides FIDnavs, stationary NMR field probes are also capable of measuring local, motion-induced field changes.

View Article and Find Full Text PDF

Introduction: Severe or complicated atheromatosis of the aortic arch represents an important and often underdiagnosed embolic source in patients with ischemic stroke. The presence of a floating thrombus has significant clinical relevance, as it is associated with a high risk of early recurrence. The aim of this study was to analyze the potential of echocardiographic examination through the suprasternal window in both the detection of embolic sources and the monitoring of the response to anticoagulant treatment in patients with mobile thrombi.

View Article and Find Full Text PDF

Objectives: Little is known about the complex interplay between urban structure and health in rapidly urbanizing cities in Nigeria.

Methods: The study broadly used very high-resolution satellite imagery and gathered primary data. With the aid of the very high-resolution imagery and identified neighborhoods, two neighborhoods each were sampled based on their classified urban structure characteristics.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!