A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Treatment concept with CAD/CAM-fabricated high-density polymer temporary restorations. | LitMetric

Tooth wear in younger patients is perceived worldwide as an increasing problem. Its etiology is multifactorial (erosion, abrasion, attrition), and its treatment is challenging for the dental practitioner specifically when a great loss of the vertical dimension of occlusion has occurred. The aim of this article is to present a treatment approach for complex cases with high loss of tooth structure using computer-aided design/computer-aided manufacturing (CAD/CAM)-fabricated temporary high-density polymer restorations without any preparations. New manufacturing technologies and innovative materials such as high-density polymers offer good possibilities for restorations during the pretreatment period. This is especially important in circumstances requiring massive corrections of color, form, or position. Pretreatment periods are indispensable in refining important factors such as lip-position dynamics as well as the correct position of the smile line, which cannot be adequately assessed in the dental laboratory. In the presented case report, CAD/CAM-fabricated non-preparation restorations were adhesively placed on the worn dentition without any further loss of tooth structure. Such an approach provides the opportunity to "test-drive" the new restoration design in terms of function, phonetics, and esthetics, thus improving the predictability of the definitive restorations design. If any change in the design is required, it can be cost-effectively achieved through simple modification or replacement of the restorations.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1708-8240.2011.00497.xDOI Listing

Publication Analysis

Top Keywords

high-density polymer
8
loss tooth
8
tooth structure
8
restorations
6
treatment concept
4
concept cad/cam-fabricated
4
cad/cam-fabricated high-density
4
polymer temporary
4
temporary restorations
4
restorations tooth
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!