While measuring knee motion in all six degrees of freedom is important for understanding and treating orthopaedic knee pathologies, traditional motion capture techniques lack the required accuracy. A variety of model-based biplane fluoroscopy techniques have been developed with sub-millimeter accuracy. However, no studies have statistically evaluated the consistency of the accuracy across motions of varying intensity or between degrees of freedom. Therefore, this study evaluated the bias and precision of a contour-based tracking technique by comparing it to a marker-based method (gold standard) during three movements with increasing intensity. Six cadaveric knees with implanted tantalum markers were used to simulate knee extension, walking and drop landings, while motion was recorded by a custom biplane fluoroscopy system. The 3D geometries of the bones were reconstructed from CT scans and anatomical coordinate systems were assigned. The position and orientation of the bone and marker models were determined for an average of 27 frames for each trial and knee joint kinematics were compared. The average bias and precision was 0.01 ± 0.65° for rotations and 0.01 ± 0.59 mm for joint translations. Rotational precision was affected by motion (p=0.04) and depended on the axis of rotation (p=0.02). However, the difference in average precision among motions or axes was small (≤ 0.13°) and not likely of consequence for kinematic measurements. No other differences were found. The contour-based technique demonstrated sub-millimeter and sub-degree accuracy, indicating it is a highly accurate tool for measuring complex three dimensional knee movements of any intensity.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jbiomech.2012.08.045DOI Listing

Publication Analysis

Top Keywords

biplane fluoroscopy
12
knee joint
8
joint kinematics
8
degrees freedom
8
bias precision
8
knee
6
accuracy
5
accuracy contour-based
4
contour-based biplane
4
fluoroscopy technique
4

Similar Publications

The shoulder joint complex is prone to musculoskeletal issues, such as rotator cuff-related pain, which affect two-thirds of adults and often result in suboptimal treatment outcomes. Current musculoskeletal models used to understand shoulder biomechanics are limited by challenges in personalization, inaccuracies in predicting joint and muscle loads, and an inability to simulate anatomically accurate motions. To address these deficiencies, we developed a novel, personalized modeling framework capable of calibrating subject-specific joint centers and functional axes for the shoulder complex.

View Article and Find Full Text PDF

This study aimed to validate the use of weightbearing computed tomography against conventional computed tomography and against bead tracking for markerless tracking of key foot and ankle bones. A left cadaveric limb was implanted with tantalum beads and underwent conventional computed tomography and weightbearing computed tomography scanning, followed by biplane fluoroscopy motion capture to simulate gait. Bone models from conventional computed tomography and weightbearing computed tomography were compared for surface differences and kinematic analysis across six joints.

View Article and Find Full Text PDF

Evaluating the functionality of x-ray angiography systems based on DICOM structured reports.

Phys Med

January 2025

Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Stockholm, Sweden; Department of Oncology-Pathology, Karolinska Institutet, Stockholm, Sweden.

Purpose: To investigate the feasibility of evaluating the functionality of x-ray angiography systems based on detailed exposure data extracted from DICOM radiation dose structured reports (RDSR).

Methods: Structured reports provide information about each x-ray irradiation event (a fluoroscopy or acquisition series) part of a clinical procedure. This data was utilized to evaluate the functionality of angiography systems installed in three pediatric and adult cardiology suites, one abdominal radiology suite, and two neurology suites.

View Article and Find Full Text PDF

Precision sampling of discrete sites identified during in-vivo functional testing in the mammalian heart.

Commun Eng

November 2024

KU Leuven, Department of Cardiovascular Sciences, Cardiovascular Imaging and Dynamics, Leuven, Belgium.

Ventricular arrhythmias after myocardial infarction (MI) originate from discrete areas within the MI border zone (BZ), identified during functional electrophysiology tests. Accurate sampling of arrhythmogenic sites for ex-vivo study remains challenging, yet is critical to identify their tissue, cellular and molecular signature. In this study, we developed, validated, and applied a targeted sampling methodology based on individualized 3D prints of the human-sized pig heart.

View Article and Find Full Text PDF

Background: The choice of angiography system could influence the outcomes of mechanical thrombectomy (MT) in the treatment of acute ischemic stroke (AIS), but its impact is not yet well understood. This study aims to compare the clinical and technical outcomes of MT performed with single plane versus biplane angiography systems.

Method: We conducted a systematic review and meta-analysis, following PRISMA guidelines, by searching PubMed, Embase, Web of Science, and Scopus to include studies on patients with AIS who underwent MT with either single plane or biplane angiography up to May 4, 2024.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!