Influence of architecture of high molecular weight linear and branched polyglycerols on their biocompatibility and biodistribution.

Biomaterials

Centre for Blood Research, Department of Pathology and Laboratory Medicine, The University of British Columbia, Life Sciences Centre, Vancouver, BC V6T 1Z3, Canada.

Published: December 2012

The availability of long circulating, multifunctional polymers is critical to the development of drug delivery systems and bioconjugates. The ease of synthesis and functionalization make linear polymers attractive but their rapid clearance from circulation compared to their branched or cyclic counterparts, and their high solution viscosities restrict their applications in certain settings. Herein, we report the unusual compact nature of high molecular weight (HMW) linear polyglycerols (LPGs) (LPG - 100; M(n) - 104 kg mol(-1), M(w)/M(n) - 1.15) in aqueous solutions and its impact on its solution properties, blood compatibility, cell compatibility, in vivo circulation, biodistribution and renal clearance. The properties of LPG have been compared with hyperbranched polyglycerol (HPG) (HPG-100), linear polyethylene glycol (PEG) with similar MWs. The hydrodynamic size and the intrinsic viscosity of LPG-100 in water were considerably lower compared to PEG. The Mark-Houwink parameter of LPG was almost 10-fold lower than that of PEG. LPG and HPG demonstrated excellent blood and cell compatibilities. Unlike LPG and HPG, HMW PEG showed dose dependent activation of blood coagulation, platelets and complement system, severe red blood cell aggregation and hemolysis, and cell toxicity. The long blood circulation of LPG-100 (t(1/2β,) 31.8 ± 4 h) was demonstrated in mice; however, it was shorter compared to HPG-100 (t(1/2β,) 39.2 ± 8 h). The shorter circulation half life of LPG-100 was correlated with its higher renal clearance and deformability. Relatively lower organ accumulation was observed for LPG-100 and HPG-100 with some influence of on the architecture of the polymers. Since LPG showed better biocompatibility profiles, longer in vivo circulation time compared to PEG and other linear drug carrier polymers, and has multiple functionalities for conjugation, makes it a potential candidate for developing long circulating multifunctional drug delivery systems similar to HPG.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.biomaterials.2012.09.007DOI Listing

Publication Analysis

Top Keywords

influence architecture
8
high molecular
8
molecular weight
8
long circulating
8
circulating multifunctional
8
drug delivery
8
delivery systems
8
vivo circulation
8
renal clearance
8
compared peg
8

Similar Publications

Recent advancements in passive wireless sensor technology have significantly extended the application scope of sensing, particularly in challenging environments for monitoring industry and healthcare applications. These systems are equipped with battery-free operation, wireless connectivity, and are designed to be both miniaturized and lightweight. Such features enable the safe, real-time monitoring of industrial environments and support high-precision physiological measurements in confined internal body spaces and on wearable epidermal devices.

View Article and Find Full Text PDF

Carbon dots (CDs) mediated g-CN (CN) is a promising visible-light-driven semiconductor in catalyzing peroxymonosulfate (PMS) for aqueous contaminants remediation. However, the poor dispersibility of powered catalyst and its challenging recyclability impede their broader application. Herein, we embedded FeN bridge within the g-CN framework and immobilized g-CN gel beads (CA/FNCCN) through a 3D cross-linking process with sodium alginate.

View Article and Find Full Text PDF

Micro-corrugated chiral nematic cellulose nanocrystal films integrated with ionic conductive hydrogels leads to flexible materials for multidirectional strain sensing applications.

Int J Biol Macromol

January 2025

State Key Laboratory of Inorganic Synthesis and Preparative Chemistry, Jilin University, 2699 Qianjin Street, Changchun 130012, PR China. Electronic address:

Multidirectional strain sensors are of technological importance for wearable devices and soft robots. Here, we report that flexible materials capable of multidirectional anisotropic strain sensing can be constructed leveraging diffusion-induced infiltration of monomers and in situ polymerization of metal ion-containing double network hydrogels in and on the surface of micro-corrugated chiral nematic cellulose nanocrystal/glucose films. Integrating the micro-corrugated cellulose nanocrystal/glucose chiral nematic films with ionic conductive hydrogels of PAA-co-AAm/sodium alginate/Al endows the materials with multidirectional mechanoelectrical resistivity and mechanochromism anisotropy.

View Article and Find Full Text PDF

We present an in-depth electrophysiological analysis of Tse5, a pore-forming toxin (PFT) delivered by the type VI secretion system (T6SS) of Pseudomonas aeruginosa. The T6SS is a sophisticated bacterial secretion system that injects toxic effector proteins into competing bacteria or host cells, providing a competitive advantage by disabling other microbes and modulating their environment. Our findings highlight the dependency of Tse5 insertion on membrane charge and electrolyte concentration, suggesting an in vivo effect from the periplasmic space.

View Article and Find Full Text PDF

The resource utilization of municipal solid waste incineration fly ash (MSWI FA) has been widely concerned at present. The chlorine removal from MSWI FA is of great significance for controlling environmental risk and improving materials properties in the process of its resource utilization. This work specifically proposes to divide the chlorine in MSWI FA into inorganic chloride and organic chloride.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!