New beam line for time-of-flight medium energy ion scattering with large area position sensitive detector.

Rev Sci Instrum

KTH Royal Institute of Technology, School of Information and Communication Technology, Integrated Circuits and Devices, P.O. Box E229, SE-16440 Kista-Stockhom, Sweden.

Published: September 2012

A new beam line for medium energy ion mass scattering (MEIS) has been designed and set up at the Ångström laboratory, Uppsala University, Sweden. This MEIS system is based on a time-of-flight (ToF) concept and the electronics for beam chopping relies on a 4 MHz function generator. Repetition rates can be varied between 1 MHz and 63 kHz and pulse widths below 1 ns are typically obtained by including beam bunching. A 6-axis goniometer is used at the target station. Scattering angle and energy of backscattered ions are extracted from a time-resolved and position-sensitive detector. Examples of the performance are given for three kinds of probing ions, (1)H(+), (4)He(+), and (11)B(+). Depth resolution is in the nanometer range and 1 and 2 nm thick Pt layers can easily be resolved. Mass resolution between nearby isotopes can be obtained as illustrated by Ga isotopes in GaAs. Taking advantage of the large size detector, a direct imaging (blocking pattern) of crystal channels are shown for hexagonal, 4H-SiC. The ToF-MEIS system described in this paper is intended for use in semiconductor and thin film areas. For example, depth profiling in the sub nanometer range for device development of contacts and dielectric interfaces. In addition to applied projects, fundamental studies of stopping cross sections in this medium energy range will also be conducted.

Download full-text PDF

Source
http://dx.doi.org/10.1063/1.4750195DOI Listing

Publication Analysis

Top Keywords

medium energy
12
energy ion
8
nanometer range
8
beam
4
beam time-of-flight
4
time-of-flight medium
4
energy
4
ion scattering
4
scattering large
4
large area
4

Similar Publications

The aim of this paper is to investigate the effect of TiC addition on the microstructure, microhardness, and wear resistance of the medium-entropy alloy Co37Cr28Ni31Al2Ti2, which is suitable for applications in aerospace, automotive, and energy industries due to its high strength and wear resistance. The samples containing 0, 10, 20, and 40 wt.% of TiC were synthesized.

View Article and Find Full Text PDF

Magnetite Nanoparticles Encapsulated with PBS-PEG for AMF Hyperthermia.

Materials (Basel)

January 2025

University Centre for Research and Development (UCRD), Department of Physics, Chandigarh University, Mohali 140413, Punjab, India.

Novel studies on typical synthesized magnetite nanoparticles were encapsulated into a poly (butylene succinate)/poly (ethylene glycol) copolymer (PBS-PEG). PBS was chosen because of its biocompatibility characteristics necessary for biomedical applications. PEG, as part of the macromolecular structure, increases the hybrid system's solubility in an aqueous environment, increasing the circulation time of the material in the bloodstream.

View Article and Find Full Text PDF

While 5-fluorouracil (5FU) plays a central role in chemotherapy for colorectal cancer (CRC), resistance to 5FU remains a major challenge in CRC treatment, and its underlying mechanisms remain unclear. In this study, we investigated the relationship between 5FU resistance acquisition, stemness, and energy metabolism. Among the two CRC cell lines, HT29 cells exhibited glycolytic and quiescent properties, while CT26 cells relied on oxidative phosphorylation (OXPHOS) for energy.

View Article and Find Full Text PDF

Genomic and Metabolomic Analyses of with Enhanced ε-Poly-l-lysine Production Through Adaptive Laboratory Evolution.

Microorganisms

January 2025

State Key Laboratory of Biobased Material and Green Papermaking, Qilu University of Technology, Shandong Academy of Sciences, Jinan 250353, China.

ε-poly-l-lysine (ε-PL), a natural food preservative, has garnered widespread attention. It is mainly produced by , but the production by wild-type strains fails to meet the demands of industrialization. To address this issue, adaptive laboratory evolution (ALE) was successfully employed in this study, subjecting CICC 11022 to environmental stresses such as acidic pH and antibiotics (rifampicin, gentamicin, and streptomycin).

View Article and Find Full Text PDF

Observing the intricate microstructure changes in abrasive flow machining with traditional experimental methods is difficult. Molecular dynamics simulations are used to look at the process of abrasive flow processing from a microscopic scale in this work. A molecular dynamics model for micro-cutting a single crystal γ-TiAl alloy with a rough surface in a fluid medium environment is constructed, which is more realistic.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!