We developed a fast multichannel detection system for pump-probe spectroscopy, capable of detecting single shot super-continuum spectra at the repetition rate (10-50 kHz) of an amplified femtosecond laser system. By tandem pumping the amplifier with three pump lasers we obtain very low noise operation, with less than 0.1% rms intensity fluctuations at the output of the amplifier. We also propose an alternative way of chopping the pump beam. With a synchronized scanning mirror two spots in the sample are illuminated by the train of pump pulses in an alternating fashion, such that when both spots are interrogated by the probe pulse, the duty cycle of the experiment is doubled.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1063/1.4750978 | DOI Listing |
J Strength Cond Res
December 2024
School of Kinesiology, University of Michigan, Ann Arbor, Michigan.
Motlagh, JG and Lipps, DB. The contribution of muscular fatigue and shoulder biomechanics to shoulder injury incidence during the bench press exercise: A narrative review. J Strength Cond Res 38(12): 2147-2163, 2024-Participation in competitive powerlifting has rapidly grown over the past two decades.
View Article and Find Full Text PDFJ Chem Phys
January 2025
Department of Chemistry, Faculty of Science, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka 819-0395, Japan.
We present velocity-map imaging (VMI) of photoelectrons detached from anions using an optical parametric amplifier operating at a repetition rate as high as 100 kHz. The light source generates femtosecond (fs) laser pulses tunable from near-infrared to ultraviolet (310-2600 nm), which interact synchronously with mass-selected anion bunches. We demonstrate this technique by measuring two-dimensional projections of photoelectrons ejected from silver trimer anions, Ag3-, across a photon energy range from 2.
View Article and Find Full Text PDFActa Neurochir (Wien)
January 2025
Department of Neurosurgery, University Medicine Greifswald, Greifswald, Germany.
Purpose: Currently available grading and classification systems for hemifacial spasm either rely on subjective assessments or are excessively intricate. Here, we make use of facial recognition and facial tracking technologies towards accurately grouping patients according to severity and characteristics of the spasms.
Methods: A retrospective review of our prospectively maintained preoperative videos database for hemifacial spasm was done.
Commun Chem
January 2025
ESRF - The European Synchrotron, 71 Avenue des Martyrs, Grenoble, France.
Serial macromolecular crystallography has become a powerful method to reveal room temperature structures of biological macromolecules and perform time-resolved studies. ID29, a flagship beamline of the ESRF 4th generation synchrotron, is the first synchrotron beamline in the world capable of delivering high brilliance microsecond X-ray pulses at high repetition rate for the structure determination of biological macromolecules at room temperature. The cardinal combination of microsecond exposure times, innovative beam characteristics and adaptable sample environment provides high quality complete data, even from an exceptionally small amount of crystalline material, enabling what we collectively term serial microsecond crystallography (SµX).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!