The ultrastructure of nymph mouthparts of the Chinese white wax scale (CWWS), Ericerus pela, consists internally of the crumena, tentorium, the stylet bundle, comprised of two mandibular stylets and two maxillary stylets, and the external clypeolabral shield, labium and sensilla. The mouthpart morphology and structures of the female nymphs are similar to the male. The mouthparts of CWWS have significantly different features in comparison to aphids and other coccids. First, the mouthparts of CWWS have a crumena and a developed tentorium. Second, the labrum is highly degraded and the labium is short and one-segmented. Third, the maxillary stylets have two 'T' type locks. Lastly, the hairs of the mouthpart are sparse and the sensilla are simple. As the labrum and labium of CWWS displayed a high degree of degradation and the tentorium was found to be highly developed, the stretching of the stylet bundle was considered to be controlled by the tentorium and crumena together. Furthermore, the degraded sensilla may be related to a specialization of feeding behavior. There were no significant differences in the length and diameter of the stylet bundles between the female and male. However, the length and diameter of the stylet bundles were significantly different between the first instar nymphs and the second instar nymphs. The first instar nymphs had stylet fascicles that were shorter and soft and initially lived on the leaves of the host trees, presumably because the leaves were thinner and they were able to pierce the leaves while the stylet bundle was relatively soft. However, the second instar nymphs had stylet bundles that were relatively hard. After the numphs molted, the degree of ossification of the stylet bundles was enhanced (increased) and the nymphs returned to the branches for living, where the strengthened stylet bundles may provide a better adaption for the thicker bark. All told, the first and second stage instar CWWS nymphs switched from leaves to the branches in order to find a safe habitat and stable food source.

Download full-text PDF

Source
http://dx.doi.org/10.3724/SP.J.1141.2012.05447DOI Listing

Publication Analysis

Top Keywords

stylet bundles
20
instar nymphs
16
stylet bundle
12
stylet
9
ericerus pela
8
nymph mouthparts
8
maxillary stylets
8
mouthparts cwws
8
length diameter
8
diameter stylet
8

Similar Publications

Background Ventricular septal pacing has long been performed using a stylet during pacemaker implantation, but with the availability of guiding catheters, His bundle pacing and left bundle branch area pacing have also been performed. However, it is not known to what extent the tip load of the ventricular lead differs when a guiding catheter is used compared with a stylet alone. In this study, the tip load was measured for different stylet stiffness and guiding catheter geometries at sites where His bundle pacing and left bundle branch area pacing were assumed.

View Article and Find Full Text PDF

Salvaged by the stylet: Procedural insights from difficult cases of left bundle branch area pacing.

Heart Rhythm

November 2024

Department of Cardiac Electrophysiology and Pacing, Arrhythmia Heart Failure Academy, The Madras Medical Mission, Chennai, Tamil Nadu, India. Electronic address:

View Article and Find Full Text PDF

Background: Left bundle branch pacing (LBBP) has emerged as a safe and effective alternative to right ventricular pacing. Traditionally, LBBP is performed with lumenless lead (LLL); however, the use of stylet-driven lead (SDL) is on rise. We aimed to assess acute success and procedural outcomes of SDL versus LLL for LBBP.

View Article and Find Full Text PDF

Background: Left bundle branch area pacing (LBBAP) has gained increased adoption globally with the use of both lumenless leads (LLLs) and stylet-driven leads (SDLs). As these leads have been developed for conventional endocardial pacing sites, concerns remain regarding the lead integrity with LBBAP.

Objectives: This study evaluates lead integrity of pacing leads used for LBBAP in a large, real-world cohort of patients with LBBAP.

View Article and Find Full Text PDF

Novel approach to left bundle branch area pacing lead implantation using a 3-dimensional stylet.

Heart Rhythm

November 2024

First Department of Cardiology, Interventional Electrocardiology and Hypertension, Jagiellonian University, Medical College, Krakow, Poland. Electronic address:

Background: Left bundle branch area pacing (LBBAP) requires implantation of the lead deep in the interventricular septum. We developed a novel implantation method that does not require dedicated delivery catheters but only a manually shaped 3-dimensional (3D) stiff stylet.

Objective: The aim of the study was to characterize procedural outcomes of this technique when used as a routine approach for LBBAP.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!