The embryological development and morphology of digital flexion creases were studied in 178 human embryos and fetuses 6-20 weeks of gestational age. The results suggest the existence of two types of digital flexion creases, that differ from each other in their development. The regular creases, with the exception of the distal crease of the proximal interphalangeal creases, and the oblique and extra creases of the irregular creases, develop concurrently with the appearance of the digital pads by about 11 weeks of gestation. The remaining creases, i.e., the distal crease of the proximal interphalangeal creases and the accessory crease develop later unrelated to the pads but, apparently, secondary to the flexion movements of the hand. Our observations further suggest that, because of their high frequencies, the oblique creases on the ulnar side of digits I and II and on the radial side of digit V and the extra creases on the proximal phalanx of digits I, III, and IV should be considered as "regular" creases. Previously unreported pads were also found on the middle phalanges at about 11 weeks of gestation. Unlike the single, large pads with high elevation, typically found on the distal phalanges, those on the middle phalanges are multiple, small, and only slightly elevated. This observation provides further support to the concept of the relationship between the fetal digital pads and the development of the epidermal ridge patterns.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/ar.1092260214 | DOI Listing |
Sci Rep
January 2025
Department of Orthopaedic Trauma, The Second Affiliated Hospital of Dalian Medical University, No. 467 Zhongshan Road, Shahekou District, Dalian, 116027, Liaoning, China.
Anterior cervical interbody fusion (ACDF) has become a classic surgical procedure for the treatment of cervical degenerative diseases, and various interbody cages are widely used in this procedure. We used 3D printing technology to produce a new type of plate-locking cage, anticipating to achieve high fusion rate with the high biomechanical stability. This study is to compare the biomechanical characteristics between a newly designed interbody cage and a conventional Zero-profile cage during ACDF using finite element analysis.
View Article and Find Full Text PDFJMIR Rehabil Assist Technol
January 2025
Department of Occupational Therapy, Faculty of Rehabilitation Medicine, University of Alberta, Edmonton, AB, Canada.
Background: Forearm, wrist, and hand impairments affect many individuals and impose a significant economic burden on health care systems. The FEPSim (flexion, extension, pronation, and supination) is designed for hand and wrist rehabilitation. It could become part of the standard care for upper extremity rehabilitation, aiming to improve range of motion, dexterity, and strength during therapeutic activities.
View Article and Find Full Text PDFActa Orthop Traumatol Turc
December 2024
Department of Orthopedics and Traumatology, Yıldırım Beyazıt University, Bilkent City Hospital, Ankara, Türkiye.
Objective: This study aimed to investigate the e!ect of arthroscopic Bankart repair (ABR) alone and ABR with an additional remplissage procedure on joint range of motion and functional results in patients with anterior shoulder instability.
Methods: This retrospective study included patients treated 1 year ago with either ABR alone or the ABR additional remplissage procedure. The Bankart lesion was determined by magnetic resonance imaging, and the amount of glenoid bone loss was determined by computed tomography.
J Orthop Surg Res
January 2025
Department of Industrial Engineering, Alma Mater Studiorum-University of Bologna, Bologna, Italy.
Background: Transfemoral osseointegrated prostheses, like other uncemented prostheses experience the risk of aseptic loosening and post-operative periprosthetic fractures, with an incidence between 3% and 30%. To date, however, osseointegrated off-the-shelf prostheses are manufactured in a limited number of sizes, and some patients do not meet the strict eligibility criteria of commercial devices. A customized osseointegrated stem was developed and a pre-clinical in vitro investigation of the stem was performed, to evaluate its biomechanical performance.
View Article and Find Full Text PDFSci Rep
January 2025
UBIC Research Group, Department of Physiotherapy, Faculty of Physiotherapy, University of Valencia, Gascó Oliag, 5, Valencia, Spain.
This study aims to assess the effect of combining virtual walking (VW) therapy with a physical exercise (PE) program compared to PE alone on lower limb strength and muscle activation in people with incomplete spinal cord injury (iSCI). 38 participants performed 3 sessions/week during 6 weeks of Experimental Intervention (EI): VW and PE; or Control intervention (CI): Placebo-VW and PE. Strength and muscle activation of main lower limb muscles were assessed.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!