AI Article Synopsis

  • A modified technique for implanting a bridging stent-graft was described for a patient with a left common iliac aneurysm.
  • The patient was a 79-year-old male who had previously undergone surgery for a ruptured abdominal aortic aneurysm.
  • A standard implant method failed, prompting the use of a wire-loop guidewire to stabilize the sheaths and successfully complete the stent-graft implantation.

Article Abstract

We described a modified technique for implanting a bridging stent-graft into an iliac branched device. A 79-year-old male who had received aortobiiliac synthetic graft surgery for a ruptured abdominal aortic aneurysm six months earlier was admitted to our unit for treatment of a left common iliac aneurysm involving the origin of the hypogastric artery. A standard technique was unsuccessful at implanting the bridging stent-graft, and therefore a wire-loop guidewire over the graft bifurcation was used to stabilize the contralateral sheaths and to complete the implantation.

Download full-text PDF

Source
http://dx.doi.org/10.4261/1305-3825.DIR.5727-12.1DOI Listing

Publication Analysis

Top Keywords

iliac branched
8
branched device
8
surgery ruptured
8
ruptured abdominal
8
abdominal aortic
8
aortic aneurysm
8
implanting bridging
8
bridging stent-graft
8
wire-loop technique
4
technique implantation
4

Similar Publications

This study aims to determine the level of origin, branching pattern and exits of the iliohypogastric and ilioinguinal nerves in relation to the psoas major muscle. Additionally, this study confirms the presence and retroperitoneal courses of the double nerves. We dissected a total of 24 iliohypogastric and ilioinguinal nerves (6 male and 6 female cadavers).

View Article and Find Full Text PDF

Introduction And Importance: Internal iliac artery aneurysms repair represents a life-threatening condition due to their anatomical position and the risk of rupture. Iliac branch devices are strongly recommended for anatomically suitable patients, but limited alternatives exist when their use is unsuitable. The use of custom-made fenestrated endografts is well documented in other aortic territories, however, their application for the treatment of internal iliac artery aneurysm remains limited.

View Article and Find Full Text PDF

Background: Vascular calcification is highly prevalent and associated with mortality in hemodialysis patients. However, extreme splanchnic arterial calcification in calciphylaxis with poor prognosis raises questions regarding the reliability of previous vascular calcification scoring methods. Therefore, this study aimed to examine the distribution characteristics of abdominal aortic branch calcification and identify a more reliable predictor of mortality in hemodialysis patients.

View Article and Find Full Text PDF

Background: Current guidelines recommend preserving at least one of the bilateral pelvic flows in patients with aortoiliac aneurysms. The sandwich parallel graft, using commercially available devices, provides a viable option for patients who fall outside the instructions for use of iliac branch devices. However, gutter endoleak remains a significant challenge.

View Article and Find Full Text PDF

Background: Acute type A aortic dissection (A-AAD) with severe acute aortic regurgitation (AR) and coronary involvement is a potentially fatal condition that causes left ventricular volume overload and catastrophic acute myocardial infarction. We present the successful management of a patient using Impella 5.5 following cardiopulmonary arrest caused by A-AAD with severe acute AR and left main trunk (LMT) obstruction.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!