Background: Detection of subclinical mastitis in dairy cows is important, as it represents a major economic challenge for the dairy industry worldwide owing to propagation of mastitis-causing pathogens and to long-term reduction in milk yield and quality. Haptoglobin (Hp) is one of the most sensitive acute phase proteins in milk during udder inflammation and as an indicator of mastitis.
Objectives: The aim of this study was to develop a rapid and sensitive immunosensor assay for measuring Hp concentration in mastitic milk.
Methods: The immunosensor was constructed by immobilizing anti-bovine Hp antibody on a gold electrode through gold nanoparticles fabricated on self-assembled L-cysteine layers. The immunosensor assay was used to measure Hp concentration in 20 milk samples positive for bacteria with a somatic cell count > 5 × 10(5) cells/mL from cows without clinical signs of mastitis. Results were compared with those obtained using a commercial ELISA kit.
Results: Reproducibility of Hp measurement and stability after storage for 20 days were good for the immunosensor assay. Measurement of Hp was linear over a range of 15-100 mg/L, with a limit of detection of 0.63 mg/L. Agreement between results obtained with the immunosensor and ELISA methods was satisfactory as analyzed using the Wilcoxon signed-rank test (Z = -1.739, P = .073).
Conclusion: An immunosensor assay for measuring Hp in milk provided rapid results and was easy to perform, facilitating its potential use in the field for the diagnosis of subclinical mastitis once a cutoff value for Hp concentration is established.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1939-165X.2012.00468.x | DOI Listing |
Anal Chim Acta
February 2025
School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China; Department of Chemistry, Sungkyunkwan University, Suwon, 16419, Republic of Korea. Electronic address:
Background: Estriol (E3) is a common estrogen responsible for regulating the female reproductive system, but excessive amount can pose health risks to humans and wild life. Therefore, sensitive and accurate detection of estriol level is crucial. A novel competitive ECL immunosensor based on a dual signal amplification strategy of AuNPs@GO@SmMoSe and Gd(MoO) was fabricated for ultrasensitive detection of estriol.
View Article and Find Full Text PDFMikrochim Acta
January 2025
College of Chemical and Pharmaceutical Engineering, Hebei University of Science and Technology, 26 Yuxiang Road, Shijiazhuang, 050018, P. R. China.
An aptamer-antibody sandwich electrochemical immunosensor was studied. FeO/MWCNTs-COOH/Nafion was modified and fixed on a glassy carbon electrode to amplify electrical signals. The antibody was coupled with AuNPs to form conjugates.
View Article and Find Full Text PDFBiosensors (Basel)
January 2025
School of Chemistry and Chemical Engineering, Zhejiang Sci-Tech University, Hangzhou 310018, China.
The sensitive detection of inflammatory biomarkers in gingival crevicular fluid (GCF) is highly desirable for the evaluation of periodontal disease. Luminol-based electrochemiluminescence (ECL) immunosensors offer a promising approach for the fast and convenient detection of biomarkers. However, luminol's low ECL efficiency under neutral conditions remains a challenge.
View Article and Find Full Text PDFBiosensors (Basel)
January 2025
State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210092, China.
Herein, a sensitive electrochemiluminescence (ECL) immunosensor is designed by immobilizing ruthenium-tagged immune complexes at flexible poly-ethylene-glycol (PEG) chains on the electrode surface, which offers more freedom for the collision of the ruthenium complex at the electrode during the initial ECL reaction. The electrochemical characterizations confirm the loose structure of the assembled layer with the immune complex, providing an increase in the current and the resultant enhanced ECL emissions. Comparing the sensors with the rigid structure, a 34-fold increase in the maximal ECL emission is recorded when PEG3400 is used as a linker.
View Article and Find Full Text PDFAnal Methods
January 2025
Defence Research and Development Establishment, Jhansi Road, Gwalior, Madhya Pradesh 474002, India.
A sandwich electrochemical immunosensor was proposed for the sensitive detection of protective antigen ( PA) toxin based on cadmium sulphide nanocrystals (CdS NCs) and polypyrrole-gold nanoparticle-modified multiwalled carbon nanotubes (PPy-AuNPs/MWCNTs). Herein, PPy-AuNPs/MWCNTs were used as a biocompatible and conducting matrix for immobilization of rabbit anti-PA antibody [RαPA antibody, capturing antibody (Ab1)] and to facilitate excellent electrical conductivity. PPy-AuNPs/MWCNTs were synthesized through a one-step chemical reaction of pyrrole and Au on the surface of MWCNTs.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!