Background: Contrast echocardiography has been shown to improve diagnostic quality, especially in technically difficult patients. However, the learning curve and increased time for preparation and image acquisition have led to low use.

Methods: We sought to determine whether the contrast echocardiography procedure performed independently by a specialized, trained sonographer could improve efficiency. In our centre, routine echocardiograms were scheduled for 1 hour, and any study exceeding 1 hour would result in patient booking cancellations. We compared the standard of care, in which a physician or nurse administers echocontrast, with a sonographer-administered program (SAP).

Results: The time to complete contrast echocardiograms was significantly reduced by the SAP strategy (43 min 17 s ± 23 min 42 s vs 1 h 1 min 6 s ± 31 min 0 s, P < 0.001). Subgroup analysis of the inpatients and outpatients demonstrated similar results. Only 10% of studies (6 of 61) in the SAP exceeded 60 minutes, compared with 45% (34 of 76) in the standard-of-care group (P < 0.001). Based on study volumes in our centre, the net improvement in productivity with the SAP could be up to 5.3% annually.

Conclusion: Sonographer-administered echocontrast is feasible and potentially removes a barrier to implementation of contrast echocardiography.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cjca.2012.07.008DOI Listing

Publication Analysis

Top Keywords

contrast echocardiography
12
min min
12
sonographer-administered echocontrast
8
feasibility sonographer-administered
4
echocontrast large-volume
4
large-volume tertiary-care
4
echocardiography
4
tertiary-care echocardiography
4
echocardiography laboratory
4
laboratory background
4

Similar Publications

TBCK (TBC1 Domain-Containing Kinase) encodes a protein playing a role in actin organization and cell growth/proliferation via the mTOR signaling pathway. Deleterious biallelic TBCK variants cause Hypotonia, infantile, with psychomotor retardation and characteristic facies 3. We report on three affected sibs, also displaying cardiac malformations.

View Article and Find Full Text PDF

Interventricular septal dissection secondary to acute inferior myocardial infarction: case series and literature review.

J Cardiothorac Surg

January 2025

Echocardiography and Vascular Ultrasound Center, The First Affiliated Hospital, Zhejiang University School of Medicine, 79 Qingchun Road, Hangzhou, 310003, China.

Background: Interventricular septal dissection is a critical disease characterized by the separation of the intraventricular septum into two layers, forming an intermediate layer with a cystic cavity that communicates with the root of the aorta or ventricle. It has low morbidity and high mortality rates.

Case Presentation: Case 1: A 58-year-old male with a history of hypertension and smoking presented to a local hospital due to chest tightness and pain for 4 days.

View Article and Find Full Text PDF

Functional mitral regurgitation is characterized by normal structures of the mitral valve and chordae tendinea, but the regurgitation occurs due to geometric changes in the left atrium and left ventricle. This condition can contribute to heart failure progression and lead to a poor prognosis. Functional mitral regurgitation is found in approximately one-third of patients with heart failure with a decreased ejection fraction.

View Article and Find Full Text PDF

Increased thrombotic events that occur in up to one-third of patients with COVID-19 are predominantly pulmonary emboli (PE), which are associated with higher severity and increased mortality. Acute PE should therefore be one of the main differential diagnoses among patients with hemodynamic instability. Early treatment of such a condition with systemic thrombolysis remains the first line of treatment especially in patients with COVID-19, which hinders further invasive intervention.

View Article and Find Full Text PDF

Impact of measurement location on direct mitral regurgitation quantification using 4D flow CMR.

J Cardiovasc Magn Reson

January 2025

Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA. Electronic address:

Background: Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) shows promise for quantifying mitral regurgitation (MR) by allowing for direct regurgitant volume (RVol) measurement using a plane precisely placed at the MR jet. However, the ideal location of a measurement plane remains unclear. This study aims to systematically examine how varying measurement locations affect RVol quantification and determine the optimal location using the momentum conservation principle of a free jet.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!