Objective: The aim of this study was to evaluate reader variability in screening mammograms according to the American College of Radiology Breast Imaging Reporting and Data System (BI-RADS) assessment and breast density categories.

Methods: A stratified random sample of 100 mammograms was selected from a population-based breast cancer screening programme in Barcelona, Spain: 13 histopathologically confirmed breast cancers and 51 with true-negative and 36 with false-positive results. 21 expert radiologists from radiological units of breast cancer screening programmes in Catalonia, Spain, reviewed the mammography images twice within a 6-month interval. The readers described each mammography using BI-RADS assessment and breast density categories. Inter- and intraradiologist agreement was assessed using percentage of concordance and the kappa (κ) statistic.

Results: Fair interobserver agreement was observed for the BI-RADS assessment [κ=0.37, 95% confidence interval (CI) 0.36-0.38]. When the categories were collapsed in terms of whether additional evaluation was required (Categories III, 0, IV, V) or not (I and II), moderate agreement was found (κ=0.53, 95% CI 0.52-0.54). Intra-observer agreement for BI-RADS assessment was moderate using all categories (κ=0.53, 95% CI 0.50-0.55) and substantial on recall (κ=0.66, 95% CI 0.63-0.70). Regarding breast density, inter- and intraradiologist agreement was substantial (κ=0.73, 95% CI 0.72-0.74 and κ=0.69, 95% CI 0.68-0.70, respectively).

Conclusion: We observed a substantial intra-observer agreement in the BI-RADS assessment but only moderate interobserver agreement. Both inter- and intra-observer agreement in mammographic interpretation of breast density was substantial. Advances in knowledge Educational efforts should be made to decrease radiologists' variability in BI-RADS assessment interpretation in population-based breast screening programmes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3500788PMC
http://dx.doi.org/10.1259/bjr/21256379DOI Listing

Publication Analysis

Top Keywords

bi-rads assessment
28
breast density
20
inter- intraradiologist
12
assessment breast
12
intra-observer agreement
12
breast
10
variability bi-rads
8
density categories
8
screening mammograms
8
population-based breast
8

Similar Publications

: This study aimed to compare ultrasound (US) findings between automated and handheld breast ultrasound (ABUS and HHUS, respectively) in small breast cancers, based on the breast imaging reporting and data system (BI-RADS) category. : We included 51 women (mean age: 52 years; range: 39-66 years) with breast cancer (invasive or DCIS), all of whom underwent both ABUS and HHUS. Patients with tumors measuring ≤1 cm on either modality were enrolled.

View Article and Find Full Text PDF

This study evaluated the association between age at first full-term pregnancy (FFTP) and mammographic breast density (MBD) in postmenopausal women. 1,034 women, age 50-69y, were recruited from the Flemish (Belgium) population-based breast cancer screening program. Participants completed a questionnaire on lifestyle and reproductive factors.

View Article and Find Full Text PDF

Background: The diagnosis of breast cancer necessitates a multifaceted approach integrating cytopathological and radiological assessments. The International Academy of Cytology (IAC) Yokohama system and Breast Imaging Reporting and Data System (BI-RADS) are fundamental frameworks in this context. This study aims to evaluate the diagnostic potential of a combined Yokohama-BI-RADS scoring system for breast lesions.

View Article and Find Full Text PDF

A Radiomic-Clinical Model of Contrast-Enhanced Mammography for Breast Cancer Biopsy Outcome Prediction.

Acad Radiol

January 2025

Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15213 (C.L., S.W.); Department of Radiology, University of Pittsburgh School of Medicine, Pittsburgh, PA 15213 (D.A., M.Z., J.S., S.W.); Department of Biomedical Informatics, University of Pittsburgh, Pittsburgh, PA 15213 (S.W.); Intelligent Systems Program, University of Pittsburgh, Pittsburgh, PA 15213 (S.W.). Electronic address:

Rationale And Objectives: In the USA over 1 million breast biopsies are performed annually. Approximately 9.6% diagnostic exams were given Breast Imaging Reporting and Data System (BI-RADS) ≥4A, most of which are 4A/4B.

View Article and Find Full Text PDF

Objective: To identify clusters of women with similar trajectories of breast density change over four longitudinal assessments and to examine the association between these trajectories and the subsequent risk of breast cancer.

Design: Retrospective cohort study.

Setting: Data from the national breast cancer screening programme, which is embedded in the National Health Insurance Service database in Korea.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!