A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of a new optical device and its feasibility in prostate cancer detection. | LitMetric

Aim: To develop a new optical device (prostate optical device, POD) for assessment of prostate tissue stiffness and evaluate its sensitivity and specificity in prostate cancer detection.

Patients And Methods: POD was tested in prostate phantoms and in patients with indications for prostate biopsy. Its sensitivity and specificity were compared to digital rectal examination (DRE) and transrectal ultrasonography (TRUS).

Results: POD was able to identify stiffness differences on each prostate phantom. 45 patients were included in the study. Sensitivity of TRUS (40%) was significantly lower to POD (85.7%) and DRE (74.3%) (p = 0.000 and p = 0.003, respectively). There was no statistical difference between POD and DRE (p = 0.221). The combination of POD and DRE showed the highest sensitivity (88.6%), positive predictive value (81.6%), and negative predictive value (42.9%) among all diagnostic tests.

Conclusions: POD identified prostatic stiffness differences with the same sensitivity of DRE performed by an experienced urologist providing an objective indication for prostate biopsy and early prostate cancer detection.

Download full-text PDF

Source
http://dx.doi.org/10.1159/000339966DOI Listing

Publication Analysis

Top Keywords

optical device
12
prostate cancer
12
prostate
9
cancer detection
8
sensitivity specificity
8
prostate biopsy
8
stiffness differences
8
pod dre
8
pod
7
sensitivity
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!