Evaluation of Masimo signal extraction technology pulse oximetry in anaesthetized pregnant sheep.

Vet Anaesth Analg

Division of Veterinary and Biomedical Sciences, Murdoch University, Perth, WA, Australia.

Published: March 2013

Objective: Evaluation of the accuracy of Masimo signal extraction technology (SET) pulse oximetry in anaesthetized late gestational pregnant sheep.

Study Design: Prospective experimental study.

Animals: Seventeen pregnant Merino ewes.

Methods: Animals included in study were late gestation ewes undergoing general anaesthesia for Caesarean delivery or foetal surgery in a medical research laboratory. Masimo Radical-7 pulse oximetry (SpO(2) ) measurements were compared to co-oximetry (SaO(2) ) measurements from arterial blood gas analyses. The failure rate of the pulse oximeter was calculated. Accuracy was assessed by Bland & Altman's (2007) limits of agreement method. The effect of mean arterial blood pressure (MAP), perfusion index (PI) and haemoglobin (Hb) concentration on accuracy were assessed by regression analysis.

Results: Forty arterial blood samples paired with SpO(2) and blood pressure measurements were obtained. SpO(2) ranged from 42 to 99% and SaO(2) from 43.7 to 99.9%. MAP ranged from 24 to 82 mmHg, PI from 0.1 to 1.56 and Hb concentration from 71 to 114 g L(-1) . Masimo pulse oximetry measurements tended to underestimate oxyhaemoglobin saturation compared to co-oximetry with a bias (mean difference) of -2% and precision (standard deviation of the differences) of 6%. Accuracy appeared to decrease when SpO(2) was <75%, however numbers were too small for statistical comparisons. Hb concentration and PI had no significant effect on accuracy, whereas MAP was negatively correlated with SpO(2) bias.

Conclusions And Clinical Relevance: Masimo SET pulse oximetry can provide reliable and continuous monitoring of arterial oxyhaemoglobin saturation in anaesthetized pregnant sheep during clinically relevant levels of cardiopulmonary dysfunction. Further work is needed to assess pulse oximeter function during extreme hypotension and hypoxaemia.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1467-2995.2012.00772.xDOI Listing

Publication Analysis

Top Keywords

pulse oximetry
16
arterial blood
12
masimo signal
8
signal extraction
8
extraction technology
8
oximetry anaesthetized
8
compared co-oximetry
8
accuracy assessed
8
blood pressure
8
pulse
5

Similar Publications

Background: This study evaluates retinal oxygen saturation and vessel density within the macula and correlates these measures in controls and subjects with type 2 diabetes (DM) with (DMR) and without (DMnR) retinopathy. Changes in retinal oxygen saturation have not been evaluated regionally in diabetic patients.

Methods: Data from seventy subjects (28 controls, 26 DMnR, and 16 DMR were analyzed.

View Article and Find Full Text PDF

Aim: The aim was to define reference ranges for cerebral oxygen saturation (crSO-ROOT) during immediate transition after birth in stable neonates.

Methods: In a prospective observational study, the crSO-ROOT was continuously measured in neonates during the first 15 min after birth. The neonatal sensor was placed on the head and fixed with a bandage.

View Article and Find Full Text PDF

The physiological sequelae of pre-term birth might influence the responses of this population to hypoxia. Moreover, identifying variables associated with development of acute mountain sickness (AMS) remains a key practically significant area of altitude research. We investigated the effects of pre-term birth on nocturnal oxygen saturation ( ) dynamics and assessed the predictive potential of nocturnal -related metrics for morning AMS in 12 healthy adults with gestational age < 32 weeks (pre-term) and 12 term-born control participants.

View Article and Find Full Text PDF

Objectives: Identifying patients in the emergency department (ED) at higher risk for in-hospital mortality can inform shared decision making and goals-of-care discussions. Electronic health record systems allow for integrated multivariable logistic regression (LR) modeling, which can provide early predictions of mortality risk in time for crucial decision making during a patient's initial care. Many commonly used LR models require blood gas analysis values, which are not frequently obtained in the ED.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!