Investigation of ion-ion-recombination at atmospheric pressure with a pulsed electron gun.

Analyst

Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Leibniz University Hanover, Appelstr. 9a, Hanover, Germany.

Published: November 2012

For future development of simple miniaturized sensors based on pulsed atmospheric pressure ionization as known from ion mobility spectrometry, we investigated the reaction kinetics of ion-ion-recombination to establish selective ion suppression as an easy to apply separation technique for otherwise non-selective ion detectors. Therefore, the recombination rates of different positive ion species, such as protonated water clusters H(+)(H(2)O)(n) (positive reactant ions), acetone, ammonia and dimethyl-methylphosphonate ions, all recombining with negative oxygen clusters O(2)(-)(H(2)O)(n) (negative reactant ions) in a field-free reaction region, are measured and compared. For all experiments, we use a drift tube ion mobility spectrometer equipped with a non-radioactive electron gun for pulsed atmospheric pressure ionization of the analytes. Both, ionization and recombination times are controlled by the duty cycle and repetition rate of the electron emission from the electron gun. Thus, it is possible to investigate the ion loss caused by ion-ion-recombination depending on the recombination time defined as the time delay between the end of the electron emission and the ion injection into the drift tube. Furthermore, the effect of the initial total ion density in the reaction region on the ion-ion-recombination rate is investigated by varying the density of the emitted electrons.

Download full-text PDF

Source
http://dx.doi.org/10.1039/c2an35849bDOI Listing

Publication Analysis

Top Keywords

atmospheric pressure
12
electron gun
12
pulsed atmospheric
8
pressure ionization
8
ion
8
ion mobility
8
reactant ions
8
reaction region
8
drift tube
8
electron emission
8

Similar Publications

Background Non-healing diabetic foot ulcers (DFUs) are significant risk factors for amputations. Though the available literature suggests that adjuvant hyperbaric oxygen therapy (HBOT) fastens the healing process and reduces the risk of amputations, its overall evidence in the reduction of amputation remains controversial. Thus, the present study aimed to compare the efficacy and safety of adjuvant HBOT and standard wound care (SWC) with SWC alone in patients with DFUs.

View Article and Find Full Text PDF

Cantilever-Enhanced Fiber-Optic Photoacoustic Spectrophone for Low-Pressure Gas Detection.

Anal Chem

January 2025

School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian 116024, Liaoning, China.

A cantilever-enhanced fiber-optic photoacoustic (PA) spectrophone is reported for trace gas detection at a low-pressure environment. A cantilever-based fiber-optic Fabry-Perot (F-P) interferometer (FPI) is utilized for simultaneous measurement of air pressure and PA pressure. Since the cantilever resonance frequency follows air pressure linearly, the fundamental frequency intensity modulation (1-IM) technique is applied to scan the frequency response of the solid PA signal from tube wall absorption for tracking the cantilever resonance frequency in real time.

View Article and Find Full Text PDF

Yellowstone Caldera is one of the largest volcanic systems on Earth, hosting three major caldera-forming eruptions in the past two million years, interspersed with periods of less explosive, smaller-volume eruptions. Caldera-forming eruptions at Yellowstone are sourced by rhyolitic melts stored within the mid- to upper crust. Seismic tomography studies have suggested that a broad region of rhyolitic melt extends beneath Yellowstone Caldera, with an estimated melt volume that is one to four times greater than the eruptive volume of the largest past caldera-forming eruption, and an estimated melt fraction of 6-28 per cent.

View Article and Find Full Text PDF

Nonthermal plasma has been extensively utilized in various biomedical fields, including surface engineering of medical implants to enhance their biocompatibility and osseointegration. To ensure robustness and cost effectiveness for commercial viability, stable and effective plasma is required, which can be achieved by reducing gas pressure in a controlled volume. Here, we explored the impact of reduced gas pressure on plasma properties, surface characteristics of plasma-treated implants, and subsequent biological outcomes.

View Article and Find Full Text PDF

The Tibetan Plateau is home to numerous glaciers that are important for freshwater supply and climate regulation. These glaciers, which are highly sensitive to climatic variations, serve as vital indicators of climate change. Understanding glacier-fed hydrological systems is essential for predicting water availability and formulating climate adaptation strategies.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!