Purpose: To understand the relationship between tibial bone defect and extent of medial release in total knee arthroplasty.
Materials And Methods: We evaluated 32 knees in 22 patients with variable degrees of tibial bone defect on medial plateau has undergone total knee arthroplasty. In this study, 31 cases had been diagnosed as degenerative osteoarthritis and 1 case was osteonecrosis. We excluded cases with infection, traumatic arthritis, or neuropathic joints. With regard to gender, 29 cases were female and 3 cases were male. The following relationships were analyzed: preoperative degrees of tibial bone defect and varus deformity; the femorotibial angle of both weight-bearing whole extremity radiogram, distractive stress radiogram, and the extent of medial release.
Results: Average tibial bone defect was 9.8±4.1 mm. Average femorotibial angle on weight-bearing whole extremity radiograph was varus 10.0°±6.2°. Average femorotibial angle on distractive stress radiograph was varus 0.7°±4.6°. Statistically the extent of medial release showed no significant relationship with the degree of tibial bone defect and femoro-tibial angle of whole extremity radiogram. However, it revealed a statistically significant relationship with the femorotibial angle on distractive radiogram (r=0.465, p=0.007).
Conclusions: Preoperative distractive stress radiograph might be a useful method to predict the extent of intraoperative medial release during total knee arthroplasty.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3438275 | PMC |
http://dx.doi.org/10.5792/ksrr.2012.24.3.146 | DOI Listing |
J Exp Orthop
January 2025
Department of Orthopaedic Surgery and Trauma University Center of Montpellier, University of Montpellier Montpellier France.
Purpose: Gap-balanced total knee arthroplasty (TKA) technique relies on initial ligament evaluation, particularly in patient-specific implantation using computer-assisted technologies. This cadaveric study aimed to compare the reproducibility and reliability of medial and lateral gap measurements between manual stress testing and dynamic ligament balancer.
Methods: Initial gap acquisitions were assessed from eight cadaveric knees (four specimens) during the same navigated TKA procedure by five differently skilled surgeons (three seniors and two juniors).
J Oral Biosci
January 2025
Bioceramics Group, Research Center for Macromoleclules and Biomaterials, National Institute for Materials Science, Tsukuba, Japan. Electronic address:
Objectives: Hydroxyapatite (HAp)/collagen (Col) cylinders with laminated collagen layers were implanted into the tibial diaphysis of rats and examined histochemically to clarify how the orientation of HAp and Col bone-like nanocomposite fibers in HAp/Col blocks affects bone resorption and formation.
Methods: HAp/Col fibers were synthesized and compressed into cylindrical blocks to mimic bone nanostructures. These were implanted into the cortical bone cavities of 10-week-old male Wistar rats with fiber bundles parallel to the tibial surface.
Acta Orthop
January 2025
Department of Orthopaedics, Spaarne Gasthuis, Hoofddorp; Department of Oral Cell Biology, Academic Centre for Dentistry (ACTA), University of Amsterdam and Vrije Universiteit Amsterdam, Amsterdam, the Netherlands.
Background And Purpose: Early migration of the uncemented cruciate-sacrificing rotating platform ATTUNE and Low Contact Stress (LCS) tibial components was classified as at-risk for aseptic loosening rates exceeding 6.5% at 15 years based on recent fixation-specific migration thresholds. In this secondary report of a randomized controlled trial (RCT) we aimed to evaluate whether the 5-year migration, inducible displacement, and the clinical outcome of the ATTUNE components were comparable to those of the LCS.
View Article and Find Full Text PDFJ Am Acad Orthop Surg
January 2025
From the Department of Orthopaedic Surgery, University of Alabama at Birmingham, Birmingham, AL (Yeager, Rutz, Strother, Spitler, and Johnson), and the Heersink School of Medicine, University of Alabama at Birmingham, Birmingham, AL (Gross, Benson, and Carter).
Introduction: Postoperative infections are a leading cause of morbidity following fracture repair. The purpose of this study is to develop a risk score predicting fracture-related infection (FRI) that will require one versus multiple revision surgeries related to infection eradication and bone healing.
Methods: This is a retrospective cohort study conducted at a single level I trauma center from 2013 to 2020.
Cureus
December 2024
Department of Orthopaedics and Traumatology, Gaziantep University Faculty of Medicine, Gaziantep, TUR.
Distraction osteogenesis is a valuable clinical technique used to address length discrepancies in long bone deformities. This procedure involves performing an osteotomy at an appropriate site in the bone and correcting the deformity through an extension system. This research aims to investigate the efficacy of a newly developed device for use in rat tibias and to provide an alternative to existing devices used in animal experiments.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!