Purpose: We have been using the flanged composite aortic prosthesis and Carrel button technique to re-attach the coronary ostia in aortic root replacement procedures at our institution over the last twenty five years. Our objective was to evaluate the long-term results of aortic root replacement with this technique.

Methods: A total of 73 patients from January 1984 to August 2010 were included in this study. The median age was 52.7 ± 14.4 years (range 28-80 years). There were 48 male and 25 female patients. 44 patients (60.3%) had annuloaortic ectasia, and 15 patients (20.5%) had acute type A aortic dissection. Marfan syndrome was recognized in 12 patients (16.5%).

Results: The early mortality rate was 5.5% (n = 4). Causes of death were multiple organ failures in two patients and sepsis in another two patients. The actuarial survival rate was 84.2% at 5 years, 64.3% at 15 years and 51.9% at 25 years. Only one patient with aortitis needed a reoperation because of coronary pseudoaneurysm after 23 years from the previous operation.

Conclusion: This modified Bentall procedure is reliable and safe, with superior long-term survival and a low rate of aortic reoperation.

Download full-text PDF

Source
http://dx.doi.org/10.5761/atcs.oa.12.01943DOI Listing

Publication Analysis

Top Keywords

modified bentall
8
bentall procedure
8
flanged composite
8
composite aortic
8
aortic prosthesis
8
aortic root
8
root replacement
8
years
7
patients
7
aortic
6

Similar Publications

Objective: Over 30% of patients presenting with acute type A aortic dissection (ATAAD) are considered high - risk or inoperable. This study aims to investigate the early and mid-term outcomes of complex endovascular aortic repair of aortic root, ascending aorta, and aortic arch among patients with ATAAD.

Methods: From January 2018 to January 2023, 29 patients who were considered high risk for open operation underwent endovascular aortic repair.

View Article and Find Full Text PDF

We present a case of an 82-year-old woman who developed sustained heart failure with left ventricular dyssynchrony after the modified Bentall procedure. Persistent circulatory instability and complete atrioventricular block suggested coronary artery stenosis. Multidetector computed tomography revealed stenosis of the grafted portion of the coronary artery.

View Article and Find Full Text PDF

Six months following modified Bentall procedure a patient presented with angina and acute ST depression. CT coronary angiogram revealed severe narrowing of the left main coronary artery. Minimal invasive off pump coronary artery bypass grafting avoided complex reoperative surgery and delivered an excellent clinical outcome.

View Article and Find Full Text PDF

Treatment With mTOR Inhibitors as Primary Immunosuppression After Combined Heart and Kidney Transplantation.

J Card Fail

December 2024

Department of Cardiovascular Diseases and Health Sciences Research and the William J. von Liebig Center for Transplantation and Clinical Regeneration, Mayo Clinic, Rochester, Minnesota. Electronic address:

Introduction: Sirolimus (SRL) mitigates cardiac allograft vasculopathy (CAV) progression and confers renal protection after heart transplantation (HT). However, its safety and efficacy in patients undergoing combined heart and kidney transplantation (HKT) are unclear. This study aimed to investigate the impact of conversion from calcineurin inhibitors (CNIs) to SRL on CAV progression, renal function, and outcomes in HKT compared with isolated HT.

View Article and Find Full Text PDF

Modified-Bentall Single-Patch Konno Enlargement Technique for Aortic Stenosis and Prosthesis-Patient Mismatch.

Ann Thorac Surg

December 2024

Department of Thoracic and Cardiovascular Surgery, Heart, Vascular, and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio; Quantitative Health Sciences, Lerner Research Institute, Cleveland Clinic, Cleveland Clinic, Cleveland, Ohio.

Article Synopsis
  • The BeSPoKE technique is a surgical method used to enlarge the aortic outflow tract in adults with complex heart issues, specifically those facing aortic stenosis and prosthesis-patient mismatch.
  • A study involving 25 adults showed significant improvement in aortic valve gradients post-surgery, with a median size increase of the prosthesis and no reports of operative mortality.
  • Postoperative complications included atrial fibrillation and heart block, but overall survival at two years was high at 92%, indicating that this technique is a safe and effective option for patients with small left ventricular outflow tracts.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!