Objective: This prospective study compared the diagnostic accuracy of imaging using an intact murine antigranulocyte antibody 99mTc-besilesomab, and a murine antibody Fab fragment 99mTc-sulesomab, in patients with suspected septically loosened total knee arthroplasty.

Methods: Images from 20 patients who underwent threephase bone scintigraphy followed by imaging using 99mTc-besilesomab (n=10) or 99mTc-sulesomab (n=10) were evaluated and compared. Final diagnosis was determined by microbiological evaluation of aspirated synovial fluid, intraoperative samples through the clinical course, or by long-term follow-up.

Results: Prosthesis infection was shown in 18 patients. At 4 and 24 h after intravenous injection, absolute uptake of 99mTc-besilesomab was significantly higher than 99mTc-sulesomab in infected knee joints. Infected-to-healthy knee activity ratios were similar at 4 and 24 h for 99mTc-besilesomab and 99mTc-sulesomab.

Conclusions: Both 99mTc-besilesomab and 99mTc-sulesomab had similar diagnostic accuracy for the detection of septic arthroplasty. If repeated use of immunoscintigraphy is needed for follow-up, 99mTc-sulesomab should be preferred over 99mTc-besilesomab since it is known to be well tolerated and without side effects or incompatibility reactions.

Download full-text PDF

Source
http://dx.doi.org/10.1177/147323001204000412DOI Listing

Publication Analysis

Top Keywords

infection patients
8
septically loosened
8
loosened total
8
total knee
8
diagnostic accuracy
8
99mtc-besilesomab
6
99mtc-sulesomab
5
intact versus
4
versus fragmented
4
fragmented 99mtc-monoclonal
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!