A validation study designed to meet the requirements of the AOAC Research Institute and the U.S. Food and Drug Administration, Center for Veterinary Medicine (FDA/CVM) was conducted for a receptor and antibody-based, immunochromatographic method (BetaStar Plus) for detection of beta-lactam antibiotic residues in raw, commingled bovine milk. The assay was found to detect amoxicillin, ampicillin, ceftiofur, cephapirin, cloxacillin, and penicillin G at levels below the FDA tolerance/safe levels, but above the maximum sensitivity thresholds established by the National Conference on Interstate Milk Shipments (NCIMS). Results of the part I (internal) and part II (independent laboratory) dose-response studies employing spiked samples were in close agreement. The test was able to detect all six drugs at the approximate 90/95% sensitivity levels when presented as incurred residues in milk collected from cows that had been treated with the specific drug. Selectivity of the assay was 100%, as no false-positive results were obtained in testing of 1031 control milk samples. Results of ruggedness experiments established the operating parameter tolerances for the BetaStar Plus assay. Results of cross-reactivity testing established that the assay detects certain other beta-lactam drugs (dicloxacillin and ticarcillin), but it does not cross-react with any of 30 drugs belonging to other classes. Abnormally high bacterial or somatic cell counts in raw milk produced no interference with the ability of the test to detect beta-lactams at tolerance/safe levels.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.5740/jaoacint.11-252 | DOI Listing |
Res Nurs Health
January 2025
Nursing Department, Universitat Rovira i Virgili, Tarragona, Spain.
The patient activation measure (PAM), a recognized measure of how active patients are in their care, is one of the most extensively used, widely translated, and tested instruments worldwide in measuring patient activation. This study aimed to assess the psychometric properties and construct validity of the Italian version of the 13-item Patient Activation Measure (PAM13-I) among patients undergoing elective laparoscopic cholecystectomy. A multicenter study was conducted across 111 surgical units in Italy.
View Article and Find Full Text PDFLangenbecks Arch Surg
January 2025
Department of General Surgery, Gansu Provincial Hospital, Lanzhou, 730000, China.
Background: In the last two decades, robotic-assisted gastrectomy has become a widely adopted surgical option for gastric cancer (GC) treatment. Despite its popularity, postoperative complications can significantly deteriorate patient quality of life and prognosis. Therefore, identifying risk factors for these complications is crucial for early detection and intervention.
View Article and Find Full Text PDFRadiology
January 2025
From the Department of Radiology, Division of Musculoskeletal Radiology, NYU Grossman School of Medicine, 660 1st Ave, 3rd Fl, Rm 313, New York, NY 10016 (S.S.W., J.V., R.K., E.H.P., J.F.); Department for Diagnostic and Interventional Radiology, Eberhard Karls University Tübingen, University Hospital Tübingen, Tübingen, Germany (S.S.W.); Department of Radiology, University Hospital Basel, Basel, Switzerland (J.V.); Department of Radiology, Hospital do Coraçao, São Paulo, Brazil (T.C.R.); Academic Surgical Unit, South West London Elective Orthopaedic Centre (SWLEOC), London, United Kingdom (D.D.); Department of Radiology, Balgrist University Hospital, Zurich, Switzerland (B.F.); Department of Radiology, Jeonbuk National University Hospital, Jeonju, Republic of Korea (E.H.P.); Research Institute of Clinical Medicine of Jeonbuk National University, Biomedical Research Institute of Jeonbuk National University Hospital, Jeonju, Republic of Korea (E.H.P.); Medscanlagos Radiology, Cabo Frio, Brazil (A.S.); Centre for Data Analytics, Bond University, Gold Coast, Australia (S.E.S.); Siemens Healthineers AG, Erlangen, Germany (I.B.); and Siemens Medical Solutions USA, Malvern, Pa (G.K.).
Background Deep learning (DL) methods can improve accelerated MRI but require validation against an independent reference standard to ensure robustness and accuracy. Purpose To validate the diagnostic performance of twofold-simultaneous-multislice (SMSx2) twofold-parallel-imaging (PIx2)-accelerated DL superresolution MRI in the knee against conventional SMSx2-PIx2-accelerated MRI using arthroscopy as the reference standard. Materials and Methods Adults with painful knee conditions were prospectively enrolled from December 2021 to October 2022.
View Article and Find Full Text PDFRadiology
January 2025
From the Departments of Biomedical Systems Informatics (S.K., Jaewoong Kim, C.H., D.Y.) and Neurology (Joonho Kim, J.Y.), Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-gu, Seoul 03722, Republic of Korea; Department of Radiology, Central Draft Physical Examination Office of Military Manpower Administration, Daegu, Republic of Korea (D.K.); Department of Radiology, Research Institute of Radiological Science and Center for Clinical Imaging Data Science (H.J.S. Y.K., S.J.), and Center for Digital Health (H.J.S., D.Y.), Yongin Severance Hospital, Yonsei University College of Medicine, Yongin, Republic of Korea; Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea (S.H.L.); Departments of Radiology (M.H.) and Neurology (S.J.L.), Ajou University Hospital, Ajou University School of Medicine, Suwon, Republic of Korea; and Institute for Innovation in Digital Healthcare, Severance Hospital, Seoul, Republic of Korea (D.Y.).
Background The increasing workload of radiologists can lead to burnout and errors in radiology reports. Large language models, such as OpenAI's GPT-4, hold promise as error revision tools for radiology. Purpose To test the feasibility of GPT-4 use by determining its error detection, reasoning, and revision performance on head CT reports with varying error types and to validate its clinical utility by comparison with human readers.
View Article and Find Full Text PDFJ Acoust Soc Am
January 2025
Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Zurich, University of Zurich, Zurich, Switzerland.
The otic capsule and surrounding temporal bone exhibit complex 3D motion influenced by frequency and location of the bone conduction stimulus. The resultant correlation with the intracochlear pressure is not sufficiently understood, thus is the focus of this study, both experimentally and numerically. Experiments were conducted on six temporal bones from three cadaver heads, with BC hearing aid stimulation applied at the mastoid and classical BAHA locations across 0.