This paper proposes a distributed system for analysis and monitoring (DSAM) of vibrations and acoustic noise, which consists of an array of intelligent modules, sensor modules, communication bus and a host PC acting as data center. The main advantages of the DSAM are its modularity, scalability, and flexibility for use of different type of sensors/transducers, with analog or digital outputs, and for signals of different nature. Its final cost is also significantly lower than other available commercial solutions. The system is reconfigurable, can operate either with synchronous or asynchronous modes, with programmable sampling frequencies, 8-bit or 12-bit resolution and a memory buffer of 15 kbyte. It allows real-time data-acquisition for signals of different nature, in applications that require a large number of sensors, thus it is suited for monitoring of vibrations in Linear Switched Reluctance Actuators (LSRAs). The acquired data allows the full characterization of the LSRA in terms of its response to vibrations of structural origins, and the vibrations and acoustic noise emitted under normal operation. The DSAM can also be used for electrical machine condition monitoring, machine fault diagnosis, structural characterization and monitoring, among other applications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3435993PMC
http://dx.doi.org/10.3390/s120607614DOI Listing

Publication Analysis

Top Keywords

acoustic noise
12
distributed system
8
linear switched
8
switched reluctance
8
vibrations acoustic
8
signals nature
8
intelligent sensor
4
sensor array
4
array distributed
4
system vibration
4

Similar Publications

On the mechanism underlying two distinct types of nonlinear sound absorption trends of porous layers.

JASA Express Lett

January 2025

Key Laboratory of Noise and Vibration Research, Institute of Acoustics, Chinese Academy of Sciences, Beijing 100190,

Through non-dimensional analysis of the nonlinear sound absorption characteristics of rigid-porous layers, the results indicate that the nonlinear sound absorption trend of a porous layer (PL) at high sound pressure levels (SPLs) mainly depends on the state of flow resistance matching. When a PL is in an under-matched state, the sound absorption coefficient (SAC) will initially rise to a maximum and then gradually decline as SPL increases. Comparatively, when it is in an over-matched state, the SAC will decrease monotonically.

View Article and Find Full Text PDF

Study on a Strategy to Improve the Image Quality and Imaging Depth for Novel Synthetic Aperture Schemes: An Experimental Investigation.

Ultrason Imaging

January 2025

Biomedical Ultrasound Imaging Laboratory, Department of Applied Mechanics and Biomedical Engineering, Indian Institute of Technology, Madras, Chennai, India.

Imaging depth remains a restriction for Synthetic Aperture (SA) approaches, even though SA techniques have been shown to overcome some of the drawbacks of Conventional Focused Beamforming (CFB) technique. This limitation is attributed to lesser energy per transmit in SA techniques compared to that of CFB technique. Therefore, in this paper, a systematic investigation is done to evaluate the improvement in imaging depth and image quality of B-mode ultrasound images in the case of SA technique using PZT transducer by boosting the input voltage to the transducer, while measuring the acoustic exposure parameters recommended in international standards.

View Article and Find Full Text PDF

Online monitoring of propofol concentrations in exhaled breath.

Heliyon

December 2024

Department of Anesthesiology, West China Hospital, Sichuan University, Chengdu, Sichuan, China.

Propofol, a widely used intravenous anesthetic agent, requires accurate monitoring to ensure therapeutic efficacy and prevent oversedation. Recent developments in modern analytical instrumentation have led to significant breakthroughs in on-line analysis of exhaled breath. This review discusses several sophisticated analytical methods that have been explored for noninvasive, real-time monitoring of propofol concentrations, including proton transfer reaction mass spectrometry, selected ion flow tube mass spectrometry, ion mobility spectrometry, and gas chromatography coupled to surface acoustic wave sensors.

View Article and Find Full Text PDF

Cepstral Peak Prominence: A Valuable Measure of Voice Outcome Severity in Patients With Unilateral Vocal Fold Paralysis.

J Voice

January 2025

Department of Otolaryngology Head and Neck Surgery, Mackay Memorial Hospital, Taipei, Taiwan; School of Medicine, Mackay Medical College, New Taipei City, Taiwan; Department of Audiology and Speech Language Pathology, Mackay Medical College, New Taipei City, Taiwan. Electronic address:

Objectives: This study investigated the relationship between the position of the paralyzed vocal fold and voice quality in patients with unilateral vocal fold paralysis (UVFP) and identified a reliable acoustic analysis tool to enhance the accuracy of voice quality assessments in this population.

Methods: A retrospective case-control study was conducted with 70 patients with UVFP diagnosed at Mackay Memorial Hospital. Acoustic features-jitter, shimmer, the harmonic-to-noise ratio (HNR), and the cepstral peak prominence smoothed (CPPs)-were analyzed using the Praat software.

View Article and Find Full Text PDF

Machine Learning-Based Estimation of Hoarseness Severity Using Acoustic Signals Recorded During High-Speed Videoendoscopy.

J Voice

January 2025

Division of Phoniatrics and Pediatric Audiology at the Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, 91054 Erlangen, Germany.

Objectives: This study investigates the use of sustained phonations recorded during high-speed videoendoscopy (HSV) for machine learning-based assessment of hoarseness severity (H). The performance of this approach is compared with conventional recordings obtained during voice therapy to evaluate key differences and limitations of HSV-derived acoustic recordings.

Methods: A database of 617 voice recordings with a duration of 250 ms was gathered during HSV examination (HS).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!