Objectives: Shorter distances from coronary ostia to the calcified aortic valve may result in occlusion with potential infarction during transcatheter aortic valve implantation. We hypothesized that preoperative CT-scan measurements might predict coronary occlusion.
Methods: Distances from the coronary ostia to the calcified aortic valve were measured during open heart aortic valve replacement in 60 consecutive patients. Distances were compared to preoperative CT-scan measurements evaluating distance of the coronary ostia as well (n = 15).
Results: The distances of the lower lip of the left and the right coronary artery ostia measured from the aortic annulus were 14.7 ± 3.9 mm and 13.4 ± 4.0 mm, respectively. The left, right and noncoronary cusp heights were 13.9 ± 2.5 mm, 12.8 ± 3.0 mm and 13.3 ± 3.1 mm, respectively. Coronary ostia topography indicated variations from the middle to the noncoronary commissure in 40% for the left and 63% for the right coronary ostium. CT-scan based measurements resulted in a distance of 12.8 ± 3.5 mm for the left and 13.9 ± 4.0 mm for the right coronary ostium, compared to 14.2 ± 4.2 mm and 13.5 ± 4.3 mm measured intraoperatively. A mild correlation between both measurements could be observed (r = 0.374, P = 0.188, left and r = 0.46, P = 0.09, n = 15).
Conclusions: CT-scan-based measurements differed from the intraoperative measurements, however preoperative CT-scan evaluation may be a useful tool to identify patients with short distance of coronaries.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3109/13645706.2012.699894 | DOI Listing |
Sci Rep
January 2025
Department of Engineering Mechanics, KTH Royal Institute of Technology, Stockholm, Sweden.
Aneurysm rupture is a life-threatening event, yet its underlying mechanisms remain largely unclear. This study investigated the fracture properties of the thoracic aneurysmatic aorta (TAA) using the symmetry-constraint Compact Tension (symconCT) test and compared results to native and enzymatic-treated porcine aortas' tests. With age, the aortic stiffness increased, and tissues ruptured at lower fracture energy [Formula: see text].
View Article and Find Full Text PDFFront Immunol
January 2025
Department of Cardiovascular Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Introduction: Calcific aortic valve disease (CAVD) is increasingly prevalent among the aging population, and there is a notable lack of drug therapies. Consequently, identifying novel drug targets will be of utmost importance. Given that type 2 diabetes is an important risk factor for CAVD, we identified key genes associated with diabetes - related CAVD via various bioinformatics methods, which provide further potential molecular targets for CAVD with diabetes.
View Article and Find Full Text PDFEur Heart J Case Rep
January 2025
Department of Cardiovascular Medicine, Sendai Kousei Hospital, 1-20 Tsutsumidori-amamiya, Aoba Ward, Sendai, Miyagi 9810914, Japan.
Background: Transcatheter edge-to-edge mitral valve repair (M-TEER) using the MitraClip system is primarily performed using the transfemoral approach. However, when this approach is not feasible, the transjugular approach can be used as an alternative.
Case Summary: A 57-year-old man presented with heart failure and persistent New York Heart Association class IV symptoms, refractory to guideline-directed medical therapy, intravenous therapy, and intra-aortic balloon pumping.
Case Rep Cardiol
December 2024
Internal Medicine Department, Isfahan University of Medical Sciences, Isfahan, Iran.
Aortic dissection (AoD) is a rare fatal condition in which tearing in the intima causes a false channel in the aorta and can lead to rupture. AoD is classified as the DeBakey classification (Types I, II, III) and Stanford classification (Types A and B). Women with underlying risk factors such as hypertension, smoking, bicuspid aortic valve, and connective tissue disorders are at risk for pregnancy-related AoD.
View Article and Find Full Text PDFCatheter Cardiovasc Interv
January 2025
Department of Cardiology, Turku University Hospital, Turku, Finland.
Background: Vascular and bleeding complications remain a concern after transfemoral transcatheter aortic valve replacement (TAVR). The impact of the sheath type on these complications remains unclear.
Methods: The prospective MARVEL registry study analyzed enrolled 500 patients undergoing large-bore transfemoral procedures and arteriotomy closure with the MANTA vascular closure device from 10 hospitals in Europe and Canada.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!