Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: To collect data about personal protective equipment (PPE) management and to provide indications for improving PPE policies in Europe.
Design: Descriptive, cross-sectional survey.
Setting And Participants: Data were collected in 48 isolation facilities in 16 European countries nominated by National Health Authorities for the management of highly infectious diseases (HIDs).
Methods: Data were collected through standardized checklists at on-site visits during February-November 2009. Indications for adequate PPE policies were developed on the basis of a literature review, partners' expert opinions, and the collected data.
Results: All facilities have procedures for the selection of PPE in case of HID, and 44 have procedures for the removal of PPE. In 40 facilities, different levels of PPE are used according to a risk assessment process, and in 8 facilities, high-level PPE (e.g., positive-pressure complete suits or Trexler units) is always used. A fit test is performed at 25 of the 40 facilities at which it is applicable, a seal check is recommended at 25, and both procedures are used at 17. Strategies for promoting and monitoring the correct use of PPE are available at 42 facilities. In case of a sudden increase in demand, 44 facilities have procedures for rapid supply of PPE, whereas 14 facilities have procedures for decontamination and reuse of some PPE.
Conclusions: Most isolation facilities devote an acceptable level of attention to PPE selection and removal, strategies for the promotion of the correct use of PPE, and ensuring adequate supplies of PPE. Fit test and seal check procedures are still not widely practiced. Moreover, policies vary widely between and within European countries, and the development of common practice procedures is advisable.