Skin graft meshing, over-meshing and cross-meshing.

Int J Surg

St Andrew's Centre for Plastic Surgery and Burns, Broomfield Hospital, Court Road, Chelmsford CM1 7TT, UK.

Published: June 2013

Introduction: Split skin grafts (SSGs) are often meshed to increase their size and allow exudate to escape. We investigated the expansion obtained with meshing, and the possibility of re-meshing skin that has already been meshed ("overmeshing"). Both useful and inadvisable permutations are illustrated.

Material And Methods: Thin porcine SSGs were sideways meshed, or meshed with ratios of 1.5:1 and 3:1. Subsequently samples were over-meshed in a variety of ratios and directions. All grafts were maximally expanded and their areas calculated.

Results: Meshed skin did not expand as much as suggested by the ratios displayed on dermacarriers. A 1:1.5 dermacarrier produced an area expansion of 1.36×, and a 1:3 meshing apparatus produced only a 1.80×area expansion. Several combinations of twice-meshed SSGs maintained integrity as long as over-meshing was done in the axis of initial meshing. Up to 2.3×expansion was obtained, by following a 1:1.5 mesh with a 1:3 mesh. We term this procedure as "overmeshing". Re-meshing in a direction orthogonal to initial meshing (cross meshing) cut the skin into small pieces.

Conclusion: Over-meshing a SSG can allow considerable further expansion, facilitating overgrafting of donor sites or simply increasing the area that can be covered with the existing harvested skin.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijsu.2012.08.013DOI Listing

Publication Analysis

Top Keywords

initial meshing
8
skin
6
meshing
6
meshed
5
skin graft
4
graft meshing
4
meshing over-meshing
4
over-meshing cross-meshing
4
cross-meshing introduction
4
introduction split
4

Similar Publications

Objective: The triply periodic minimal surface (TPMS) Gyroid porous scaffolds were built with identical porosity while varying pore sizes were used by fluid mechanics finite element analysis (FEA) to simulate the microenvironment. The effects of scaffolds with different pore sizes on cell adhesion, proliferation, and osteogenic differentiation were evaluated through calculating fluid velocity, wall shear stress, and permeability in the scaffolds.

Methods: Three types of gyroid porous scaffolds, with pore sizes of 400, 600 and 800 μm, were established by nTopology software.

View Article and Find Full Text PDF

Objective: To study the influence of bracket base meshes on shear bond strength and observe them using a scanning electron microscopy (SEM) before and after debonding.

Methods: Ninety brackets were divided into nine groups of 10 samples each: G1-Alexander, G2-Mini Sprint Brackets, G3-In-Ovation R CCO, G4-Gemini SL Self-Ligating Bracket, G5-Classic mini 2G Stylus, G6-Gemini Metal Brackets, G7-Clarity Advanced, G8-Crystall-Ize, and G9-Ceramic Series Flexx 2G. Groups G1 to G6 and G7 to G9 consisted of metallic and aesthetic brackets, respectively.

View Article and Find Full Text PDF

Tuning multi-scale pore structures in carbonaceous films via direct ink writing and sacrificial templates for efficient indoor formaldehyde removal.

J Hazard Mater

January 2025

Key Laboratory of Coastal Urban Resilient Infrastructures (Ministry of Education), College of Civil and Transportation Engineering, Shenzhen University, Shenzhen 518060, China; Beijing Key Laboratory of Indoor Air Quality Evaluation and Control, Department of Building Science, Tsinghua University, Beijing 100084, China; State Key Laboratory of Intelligent Geotechnics and Tunnelling, Shenzhen University, Shenzhen 518060, China; State Key Laboratory of Subtropical Building and Urban Science, Shenzhen 518060, China; Key Laboratory of Eco Planning & Green Building (Tsinghua University), Ministry of Education, Beijing 100084, China. Electronic address:

The primary challenges impeding the extensive application of adsorption for indoor air purification have been low efficiency and effective capacity. To fill the research gap, we developed carbonaceous net-like adsorption films featuring multi-scale porous structures for efficient indoor formaldehyde removal. By optimizing the interfacial mass transfer and internal diffusion, we designed macro- to mesoscale meshes on the film surface and micro- to nano-scale pores within the materials, which were achieved by direct-ink-writing (DIW) printing and sacrificial template methods, respectively.

View Article and Find Full Text PDF

The transient plane source (TPS) method heat transfer model was established. A body-fitted coordinate system is proposed to transform the unstructured grid structure to improve the speed of solving the heat transfer direct problem of the winding probe. A parallel Bayesian optimization algorithm based on a multi-objective hybrid strategy (MHS) is proposed based on an inverse problem.

View Article and Find Full Text PDF

Irrespective of the specific see-through device, obtaining optimal transparency remains the primary goal. In this work, we introduce a general strategy to enhance the transparency of various see-through devices. We achieve this by structuring the colored functional materials into imperceptible three-dimensional mesh lines, addressing a common challenge in multi-layer structures where each layer causes a reduction in transparency due to their color or opacity.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!