Objectives: In three experiments, we studied the detection of multiple abnormality types using the satisfaction of search (SOS) paradigm, the provision of a computer-aided detection (CAD) of pulmonary nodules and a focused nodule detection task.

Methods: 51 chest CT examinations (24 that demonstrated subtle pulmonary nodules and 27 that demonstrated no pulmonary nodules) were read by 15 radiology residents and fellows under two experimental conditions: (1) when there were no other abnormalities present except test abnormalities in the exams (non-SOS condition), and (2) when other abnormalities were present in the exams (SOS condition). Trials from the two conditions were intermixed. Readers were invited to return for two sessions: one in which the SOS condition was repeated with a simulated CAD; another in which only the non-SOS condition was presented. Detection accuracy was measured using receiver operating characteristic (ROC) analysis.

Results: An SOS effect (reduced detection accuracy for the test nodules in the presence of the diverse added abnormalities) was not found. Average accuracy was much higher when the CAD prompt was provided, without cost in the detection of the added abnormalities. Accuracy for detecting nodules appearing without intermixed SOS trials was also substantially improved.

Conclusions: CT interpretation was highly task dependent. Nodule detection was poor in the general search task. Therefore, CAD may offer a greater performance improvement than demonstrated in experiments assessing CAD using focused search. The absence of SOS may be due to limited nodule detection even without other abnormalities. Advances in knowledge CAD prompts of nodules increase the detection accuracy of nodules and decrease the time to detection-without impairing the detection accuracy-of non-nodule abnormalities.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3615394PMC
http://dx.doi.org/10.1259/bjr/18244135DOI Listing

Publication Analysis

Top Keywords

pulmonary nodules
12
nodule detection
12
detection accuracy
12
detection
10
abnormalities exams
8
non-sos condition
8
sos condition
8
detection abnormalities
8
nodules
7
abnormalities
7

Similar Publications

Objectives: To investigate the image quality and diagnostic performance with ultra-low dose dual-layer detector spectral CT (DLSCT) by various reconstruction techniques for evaluation of pulmonary nodules.

Materials And Methods: Between April 2023 and December 2023, patients with suspected pulmonary nodules were prospectively enrolled and underwent regular-dose chest CT (RDCT; 120 kVp/automatic tube current) and ultra-low dose CT (ULDCT; 100 kVp/10 mAs) on a DLSCT scanner. ULDCT was reconstructed with hybrid iterative reconstruction (HIR), electron density map (EDM), and virtual monoenergetic images at 40 keV and 70 keV.

View Article and Find Full Text PDF

Objectives: To evaluate the image quality and lung nodule detectability of ultralow-dose CT (ULDCT) with adaptive statistical iterative reconstruction-V (ASiR-V) post-processed using a deep learning image reconstruction (DLIR)-based image domain compared to low-dose CT (LDCT) and ULDCT without DLIR.

Materials And Methods: A total of 210 patients undergoing lung cancer screening underwent LDCT (mean ± SD, 0.81 ± 0.

View Article and Find Full Text PDF

Introduction: There is little information in the literature on the early, sub-clinical stage and laboratory test results in patients with primary mucosa-associated lymphoid tissue (MALT) lymphoma of the lung, a rare disease.

Case Description: In a 75-year-old man, an open lung biopsy-confirmed diagnosis of primary pulmonary lymphoma was preceded by almost six months of anaemia of inflammatory disease and monocytosis without any pulmonary symptoms. When he developed a dry cough, increasing dyspnoea and marked weight loss, these changes deepened and became associated with reactive thrombocytosis; markedly increased ferritin and C-reactive protein (positive acute-phase reactants), as well as reduced albumin and transferrin (negative acute-phase reactants).

View Article and Find Full Text PDF

We would like to present a 49-year-old female patient who was presented with a vulva lesion and palpable inguinal lymph nodes who were diagnosed with disseminated multiorgan involvement of high grade diffuse large B-cell lymphoma. The F-fluorodeoxyglucose positron emission tomography computerized tomography imaging showed multiple cervical, axillary, and abdominal lymph nodes, pulmonary nodules as well as gross hypermetabolic vulvar lesion.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?