Introduction: The use of self-expandable stents to treat postoperative leaks and fistula in the upper gastrointestinal (GI) tract is an established treatment for leaks of the upper GI tract. However, lumen-to-stent size discrepancies (i.e., after sleeve gastrectomy or esophageal resection) may lead to insufficient sealing of the leaks requiring further surgical intervention. This is mainly due to the relatively small diameter (≤30 mm) of commonly used commercial stents. To overcome this problem, we developed a novel partially covered stent with a shaft diameter of 36 mm and a flare diameter of 40 mm.
Methods: From September 2008 to September 2010, 11 consecutive patients with postoperative leaks were treated with the novel large diameter stent (gastrectomy, n = 5; sleeve gastrectomy, n = 2; fundoplication after esophageal perforation, n = 2; Roux-en-Y gastric bypass, n = 1; esophageal resection, n = 1). Treatment with commercially available stents (shaft/flare: 23/28 mm and 24/30 mm) had been unsuccessful in three patients before treatment with the large diameter stent. Due to dislocation, the large diameter stent was anchored in four patients (2× intraoperatively with transmural sutures, 2× endoscopically with transnasally externalized threads).
Results: Treatment was successful in 11 of 11 patients. Stent placement and removal was easy and safe. The median residence time of the stent was 24 (range, 18-41) days. Stent dislocation occurred in four cases (36 %). It was treated by anchoring the stent. Mean follow-up was 25 (range, 14-40) months. No severe complication occurred during or after intervention and no patient was dysphagic.
Conclusions: Using the novel large diameter, partially covered stent to seal leaks in the upper GI tract is safe and effective. The large diameter of the stent does not seem to injure the wall of the upper GI tract. However, stent dislocation sometimes requires anchoring of the stent with sutures or transnasally externalized threads.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00464-012-2507-x | DOI Listing |
Sci Rep
January 2025
Department of Ophthalmology, Graduate School of Medicine and Pharmaceutical Sciences, University of Toyama, 2630 Sugitani, Toyama, 930-0194, Japan.
To assess retinal pigment epithelium (RPE) tears in eyes which underwent pars plana vitrectomy (PPV) for submacular hemorrhage (SMH) secondary to age-related macular degeneration and to investigate the prognostic factors of visual outcomes. This study was a retrospective, observational case series that included 24 eyes of 24 patients who underwent PPV with subretinal tissue plasminogen activator and air for SMH. RPE tears were investigated using spectral-domain or swept-source optical coherence tomography images with raster scan, combined confocal scanning laser ophthalmoscope near-infrared images and color fundus photographs.
View Article and Find Full Text PDFCell Rep Methods
January 2025
Department of Nutrition, University of California, Davis, Davis, CA 95616, USA. Electronic address:
High-density lipoprotein (HDL) particle diameter distribution is informative in the diagnosis of many conditions, including Alzheimer's disease (AD). However, obtaining an accurate HDL size measurement is challenging. We demonstrated the utility of measuring the diameter of more than 1,800,000 HDL particles with the deep learning model YOLOv7 (you only look once) from micrographs of 183 HDL samples, including patients with dementia or normal cognition (controls).
View Article and Find Full Text PDFColloids Surf B Biointerfaces
January 2025
Shaanxi Key Laboratory of Catalysis, School of Chemistry and Environment Science, Shaanxi University of Technology, No.1 East 1st Ring Road, Hanzhong, Shaanxi 723001, PR China.
The advantages of large surface area, high volume ratio, good biocompatibility, and controllable surface functionalization make hollow mesoporous silica nanoparticles (HMSNs) an ideal drug carrier. HMSNs can achieve high efficiency, targeting, and controlled release by adjusting the microstructure and surface modification of its particles, which makes it broad application prospects in the field of medical therapy, especially in cancer therapy. Numerous studies have shown that preparation method, shape, particle size, hollow inner diameter, aperture and wall thickness of the HMSNs, the characteristics of the drugs, the interaction between the drugs and the carriers, and the external environment all closely affect the drug delivery, release, and efficacy.
View Article and Find Full Text PDFJ Biomech
January 2025
School of Mechanical Engineering, Hefei University of Technology, Hefei, Anhui 230009, PR China. Electronic address:
Hemodynamic processes from the portal vein(PV) to the inferior vena cava(IVC) were mimicked for three patients with portal hypertension(PH) and the effects of stent parameters on the outcomes of transjugular intrahepatic portosystemic shunt(TIPS) were investigated through computational fluid dynamics(CFD). The liver region was simulated with porous media model and the spatial distributions of superior mesenteric vein(SMV) and splenic vein(SV) blood were solved through the Eulerian multiphase model. The present method is able to simulate the PH flow and predict the PV pressure, the stent shunt rate and the SMV blood proportion after TIPS treatment.
View Article and Find Full Text PDFPlant Dis
January 2025
Hainan University School of Tropical Agriculture and Forestry, Haikou, Hainan, China;
Katsumada galangal seed ( K. Schum) is an important member of the Zingiberaceae family, with both medicinal value and culinary applications (Park et al. 2020).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!