Wire-reinforced endotracheal tube fire during tracheostomy -A case report-.

Korean J Anesthesiol

Department of Anesthesiology and Pain Medicine, College of Medicine, Chungbuk National University, Cheongju, Korea.

Published: August 2012

Every operation could have a fire emergency, especially in the case of a tracheostomy. When a flammable gas meets a source of heat, the danger of fire is remarkable. A tracheal tube filled with a high concentration of oxygen is also a great risk factor for fire. Intra-tracheal tube fire is a rare, yet critical emergency with catastrophic consequences. Thus, numerous precautions are taken during a tracheostomy like, use of a special tube to prevent laser damage, ballooning of the tube with normal saline instead of air, and dilution of FiO(2) with helium or nitrogen. Since the first recorded cases on tube fires, most of the fires were initiated in the balloon and the tip. In the present case report, however, we came across a fire incidence, which originated from the wire.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3427809PMC
http://dx.doi.org/10.4097/kjae.2012.63.2.157DOI Listing

Publication Analysis

Top Keywords

tube fire
8
tube
6
fire
6
wire-reinforced endotracheal
4
endotracheal tube
4
fire tracheostomy
4
tracheostomy case
4
case report-
4
report- operation
4
operation fire
4

Similar Publications

Does the TruBlue Laser Set Microlaryngoscopy Equipment on Fire? A Systematic Evaluation.

Laryngoscope

December 2024

Department of Surgery, Division of Otolaryngology-Head and Neck Surgery, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, Wisconsin, U.S.A.

Introduction: The risk of fire during laser microlaryngoscopy is well known. However, limited information is available about fire risk with the novel TruBlue laser. This study systematically evaluates its interactions with common surgical supplies, offering valuable insights into safety considerations for surgeons.

View Article and Find Full Text PDF

Aim: Guidelines recommend supraglottic airways (e.g. laryngeal tube, LT) for out-of-hospital cardiac arrest (OHCA) if providers are not skilled in endotracheal intubation (ETI).

View Article and Find Full Text PDF

Background: Common causes of air leakage around an endotracheal tube include insufficient endotracheal tube cuff inflation and damage to the cuff, while damage to the pilot balloon or pilot balloon tubing is relatively rare.

Case Presentation: A 74-year-old female with vertebral osteomyelitis was scheduled for an extreme lateral interbody fusion followed posterior fixation. A fiber-optic light was utilized as part of the surgical illuminator.

View Article and Find Full Text PDF

Cadaveric Study on the Safety of High-Flow Nasal Oxygen in Laser Microlaryngeal Surgery.

Laryngoscope

January 2025

Department of Otolaryngology, Division of Laryngology, Head and Neck Institute, Cleveland Clinic, Cleveland, Ohio, U.S.A.

Introduction: High-flow nasal oxygen (HFNO), or transnasal humidified rapid-insufflation ventilatory exchange (THRIVE), is a technique providing apneic oxygenation and a degree of ventilation during microlaryngeal surgery. Its use with laser has been questioned due to concern for airway fire. For fire to occur, a triad of ignition source, oxidizer, and fuel source must be present.

View Article and Find Full Text PDF

Objective: To evaluate the association between wildfire exposure in pregnancy and spina bifida risk.

Methods: This retrospective cohort study used the California Office of Statewide Health Planning and Development Linked Birth File with hospital discharge data between 2007 and 2010. The Birth File data were merged with the California Department of Forestry and Fire Protection data of the same year.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!