Recently, a new device for noninvasive assessment of central systolic blood pressure (cSBP) (BPro device with A-Pulse) was approved by the US Food and Drug Administration, but available data are limited. In 52 patients undergoing invasive elective cardiac evaluation, central hemodynamics were measured invasively. Immediately thereafter, radial artery waveforms were sampled by two noninvasive techniques, the BPro and, as a comparator, the SphygmoCor System. Then, central hemodynamics were measured invasively for a second time. The invasively recorded cSBP (137 ± 27 mm Hg) did not differ with both noninvasively assessed cSBP by BPro (136 ± 21 mm Hg, P = .627 vs invasive cSBP) and by SphygmoCor (136 ± 23 mm Hg, P=.694 vs invasive cSBP) and correlated highly between invasively recorded and both noninvasively assessed cSBP. However, using Bland-Altman plots, spreading of compared data of both devices can be found (BPro: 0.87 ± 13 mm Hg vs invasive cSBP; SphygmoCor: 0.77 ± 14 mm Hg vs invasive cSBP). There was an excellent correlation of both noninvasive devices for the calculation of cSBP (r=0.961, P<.001). cSBP differed by only 0.1 ± 6 mm Hg (P=.913) between the two noninvasive devices. Therefore, both noninvasive devices showed an accurate agreement in cSBP compared with invasively measured cSBP.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8108982 | PMC |
http://dx.doi.org/10.1111/j.1751-7176.2012.00682.x | DOI Listing |
J Clin Hypertens (Greenwich)
January 2025
Department of Geriatrics, Medical Center on Aging of Shanghai Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China.
The aim of this study was to explore whether 24-h ambulatory central (aortic) blood pressure (BP) has an advantage over office central aortic BP in screening for hypertension-mediated target organ damage (HMOD). A total of 714 inpatients with primary hypertension and the presence of several cardiovascular risk factors or complications involving clinical HMOD were enrolled. Twenty-four hour central aortic BP was measured by means of a noninvasive automated oscillometric device (Mobil-O-Graph).
View Article and Find Full Text PDFAm J Hypertens
December 2024
Department of Primary Care Research Unit of Salamanca (APISAL), Salamanca Primary Healthcare Management, Castilla y León Regional Health Authority (SACyL), Institute of Biomedical Research of Salamanca (IBSAL), Salamanca, Spain.
Background: The progression of central blood pressure (CBP) values and central hemodynamic parameters and its relationship with cardiovascular risk factors is quite unknown. We sought to investigate this association in a Spanish adult population without cardiovascular diseases.
Methods: Prospective observational research with a 5-year follow-up.
J Hum Hypertens
December 2024
Heart Research, Murdoch Children's Research Institute, Parkville, VIC, Australia.
High blood pressure (BP) in childhood is a recognised precursor of elevated cardiovascular risk in adulthood. Brachial BP is normally used for clinical decision making, but central BP may be a better marker of pressure load on the heart. There is a paucity of validated non-invasive, automated devices for estimating central BP in children and adolescents.
View Article and Find Full Text PDFPLoS Genet
September 2024
Division of Cardiovascular Medicine, Department of Internal Medicine, University of Michigan Medical School, Ann Arbor, Michigan, United States of America.
J Pers Med
August 2023
Research Center for Epidemiology and Biostatistics, Sorbonne Paris Cité (CRESS), Université Paris Cité, AP-HP, Diagnosis and Therapeutic Center, Hôtel-Dieu, 1, Place du Parvis Notre Dame, 75004 Paris, France.
Backround: Central systolic blood pressure (cSBP) provides valuable clinical and physiological information. A recent invasive study showed that cSBP can be reliably estimated from mean (MBP) and diastolic (DBP) blood pressure. In this non-invasive study, we compared cSBP calculated using a Direct Central Blood Pressure estimation (DCBP = MBP/DBP) with cSBP estimated by radial tonometry.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!