Purpose: To investigate the relevance of initial temperature of the polymethylmethacrylate (PMMA) plates used as a target for photoablation during calibration of excimer lasers performed in daily clinical routine.

Methods: An experimental argon fluoride excimer laser with a repetition rate of 1050 Hz, a radiant exposure of 500 mJ/cm², and single pulse energy of 2.1 mJ was used for photoablation of PMMA plates. The initial plate temperature varied from 10.1°C to 75.7°C. The initial temperature was measured with an infrared camera and the central ablation depth of a myopic ablation of -9.00 diopters (D) with an optical zone of 6.5 mm was measured by means of a surface profiling system.

Results: The ablation depth increased linearly from 73.9 to 96.3 μm within a temperature increase from 10.1°C to 75.7°C (increase rate of 0.3192 μm/K). The linear correlation was found to be significant (P<.05) with a coefficient of determination of R²=0.95. Based on these results and assuming a standard room temperature of 20°C, optimal plate temperature was calculated to be 15°C to 25°C to maintain an ablation within 0.25 D.

Conclusions: The temperature of PMMA plates for clinical laser calibration should be controlled ideally within a range of approximately ±5°C, to avoid visually significant refractive error due to calibration error. Further experimental investigations are required to determine the influence of different initial corneal temperatures on the refractive outcome.

Download full-text PDF

Source
http://dx.doi.org/10.3928/1081597X-20120823-02DOI Listing

Publication Analysis

Top Keywords

pmma plates
12
initial temperature
8
101°c 757°c
8
ablation depth
8
temperature
5
initial
4
initial surface
4
surface temperature
4
temperature pmma
4
plates daily
4

Similar Publications

Introduction And Importance: Postoperative dysphagia following anterior cervical discectomy fusion (ACDF) for cervical disc herniation is still poorly understood. Dysphagia after anterior spinal cervical approach is mild and transient. Here, the authors present a rare case suffering with severe progressive dysphagia for over 1 year after 20 years of ACDF due to expulsed bone cement abutting the esophagus which was successfully removed after reoperation.

View Article and Find Full Text PDF

Flexible and Compact PVDF/PMMA-Based Gel Polymer Electrolytes for High-Performance Sodium Metal Batteries.

Macromol Rapid Commun

December 2024

School of Energy Science and Engineering and Jiangsu Key Laboratory of Process Enhancement and New Energy Equipment Technology, Nanjing Tech University, Nanjing, Jiangsu Province, 211816, China.

Sodium is gaining recognition as a promising alternative to lithium for battery applications, particularly in sodium metal batteries (SMBs), where the performance is critically influenced by the choice of electrolyte. Although conventional organic liquid electrolytes are widely used, they pose significant issues. Gel membrane (GM)-based electrolytes have demonstrated enhanced reliability and stability.

View Article and Find Full Text PDF

Cranioplasty to restore calvarial defects involves reconstruction with alloplastic materials or autologous tissues in order to provide the best protection to all intracranial contents. Sometimes, autologous bone may not be available; therefore, different materials have emerged such as polymethylmethacrylate plate, titanium mesh, and hydroxyapatite. However, when it is impossible to replace the autologous bone, the aesthetic result is generally unsatisfactory.

View Article and Find Full Text PDF

This article presents a novel approach to targeted 4f pulse shaping using phase plates fabricated by single-point diamond turning (SPDT) machining. The manufacturing of the phase plates using SPDT is versatile, cost-effective, fast, robust, and applicable across a wide range of optical materials, spanning from visible to far-infrared spectra (e.g.

View Article and Find Full Text PDF

Pelvic osteotomy for pelvic canal stenosis after malunion pelvic fractures in cats.

J Feline Med Surg

October 2024

Laboratory of Veterinary Surgery, Department of Veterinary Science, Faculty of Veterinary Medicine, Nippon Veterinary and Life Science University, Tokyo, Japan.

Objectives: The aim of this study was to assess the efficacy of pelvic osteotomy and ventral fixation of the ischium using cortical screws and polymethylmethacrylate (PMMA) for feline pelvic canal stenosis (PCS) associated with malunion after conservative management of pelvic fractures.

Methods: Surgical pelvic enlargement was performed for PCS in six cats. The medical records, including information on the patients, surgical procedures, defecation and complications, were reviewed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!