Two-axis solar tracking accomplished through small lateral translations.

Appl Opt

Department of Electrical and Computer Engineering, University of California, San Diego, 9500 Gilman Drive, Mail Code 0409, La Jolla, California 92093, USA.

Published: September 2012

High-concentration solar-power optics require precise two-axis tracking. The planar micro-optic solar concentrator uses a lenslet array over a planar waveguide with small reflective facets at the focal point of each lenslet to couple incident light into the waveguide. The concentrator can use conventional tracking, tilting the entire assembly, but the system geometry also allows tracking by small lateral translation of the lenslet relative to the waveguide. Here, we experimentally demonstrate such microtracking with the existing concentrator optics and present optimized optical designs for systems with higher efficiency and angle range.

Download full-text PDF

Source
http://dx.doi.org/10.1364/AO.51.006117DOI Listing

Publication Analysis

Top Keywords

small lateral
8
two-axis solar
4
tracking
4
solar tracking
4
tracking accomplished
4
accomplished small
4
lateral translations
4
translations high-concentration
4
high-concentration solar-power
4
solar-power optics
4

Similar Publications

Influence of Axial Rotation Between the Femoral Neck and Ankle Joint on Kinematics in Normal Knees: A Cross-Sectional Study.

J Am Acad Orthop Surg Glob Res Rev

January 2025

From the Department of Orthopedic Surgery, Faculty of Medicine, The University of Tokyo, Bunkyo, Tokyo (Dr. Kono, Dr. Taketomi, Dr. Kage, Dr. Inui, and Dr. Tanaka); the Department of Information Systems, Faculty of Engineering, Saitama Institute of Technology, Fukaya, Saitama (Dr. Yamazaki); the Department of Orthopedic Biomaterial Science, Osaka University Graduate School of Medicine, Suita, Osaka (Dr. Tamaki, and Dr. Tomita); the Department of Orthopedic Surgery, Saitama Medical University, Saitama Medical Center, Kawagoe, Saitama (Dr. Inui); and the Department of Health Science, Graduate School of Health Science, Morinomiya University of Medical Sciences, Suminoe, Osaka, Japan (Dr. Tomita).

Background: The effect of axial rotation between the femoral neck and ankle joint (total rotation [TR]) on normal knees is unknown. Therefore, this study aimed to investigate the TR effect on normal knee kinematics.

Methods: Volunteers were divided into groups large (L), intermediate (I), and small (S), using hierarchical cluster analysis based on TR in the standing position.

View Article and Find Full Text PDF

Nanoporous graphene (NPG), laterally bonded carbon nanoribbons, is a promising platform for controlling coherent electron propagation in the nanoscale. However, for its successful device integration NPG should ideally be on a substrate that preserves or enhances its anisotropic transport properties. Here, using an atomistic tight-binding model combined with nonequilibrium Green's functions, we study NPG on graphene and show that their electronic coupling is modulated as a function of the interlayer twist angle.

View Article and Find Full Text PDF

Evaluating Outcomes of Step-Cut Osteotomy for Pediatric Cubitus Deformities.

J Orthop Case Rep

January 2025

Department of Orthopaedic Surgery, Jawaharlal Nehru Medical College, Aligarh Muslim University, Aligarh, Uttar Pradesh, India.

Introduction: Supracondylar fractures in children often result in malunion and subsequent cubitus varus or valgus deformity. While often considered cosmetic, these deformities can lead to pain, functional impairment, and other complications. Corrective osteotomy is a common treatment option, with step-cut osteotomy being a preferred method due to its effectiveness and relative simplicity.

View Article and Find Full Text PDF

Background: Radiotherapy is the primary treatment modality for most head and neck cancers (HNCs). Despite the addition of chemotherapy to radiotherapy to enhance its tumoricidal effects, almost a third of HNC patients suffer from locoregional relapses. Salvage therapy options for such recurrences are limited and often suboptimal, partly owing to divergent tumor and microenvironmental factors underpinning radioresistance.

View Article and Find Full Text PDF

Background: A large urogenital hiatus in Level III results in a higher risk of developing pelvic organ prolapse after birth and failure after prolapse surgery. Deepening of the pelvic floor and downward rotation of the levator plate have also been linked to prolapse. Currently we lack data that evaluates how these measures relate to one another and to prolapse occurrence and size.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!