In-shoe center of pressure: indirect force plate vs. direct insole measurement.

Foot (Edinb)

Biorobotics and Biomechanics Lab, Faculty of Mechanical Engineering, Technion-Israel Institute of Technology, Haifa, Israel.

Published: December 2012

Background: In-shoe center of pressure (COP) measurement is essential in biomechanics. COP can be measured directly utilizing pressure-sensitive insoles, or calculated indirectly via force plate-generated data. While the latter does not require the use of additional measurement hardware (shoe insoles), its precision at calculating in-shoe COP has not been determined. Our purpose was to ascertain the precision of force plate in-shoe COP calculations and enhance their accuracy through a mathematical algorithm.

Methods: Twelve male students participated in the study. In-shoe COP was measured synchronously via the Pedar-X insole system and AMTI force plates, comparing the measurements of both systems. A mathematical algorithm was created to improve agreement between the systems and comparisons were recalculated.

Results: The two methods showed different measurements of in-shoe COP. The medio-lateral (ML) and anterior-posterior (AP) Pearson correlation coefficients between systems were 0.44 ± 0.35 and 0.99 ± 0.01, and the ML and AP RMS errors were 6.3 ± 3.0 mm and 43.0 ± 12.5 mm, respectively. Using a mathematical algorithm, the differences between the measurements of each system could be reduced significantly (all P<0.001).

Conclusions: Without adjustment, force plates give an approximate location of the COP. Using an adjustment model greatly improves the accuracy of the COP trajectory during stance.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.foot.2012.07.001DOI Listing

Publication Analysis

Top Keywords

in-shoe cop
16
in-shoe center
8
center pressure
8
force plate
8
cop measured
8
mathematical algorithm
8
in-shoe
6
cop
6
pressure indirect
4
force
4

Similar Publications

Background: Knee osteoarthritis (KOA) is an irreversible degenerative disease that characterized by pain and abnormal gait. Radiography is typically used to detect KOA but has limitations. This study aimed to identify changes in plantar pressure that are associated with radiological knee osteoarthritis (ROA) and to validate them using machine learning algorithms.

View Article and Find Full Text PDF

Novices cannot fill the examiners' shoes: Evidence of footwear examiners' expertise in shoe comparisons.

Sci Justice

September 2023

Office of the Chief Forensic Scientist, Victoria Police Forensic Services Department, 31 Forensic Drive Macleod, VIC 3085, Australia.

The value of a footwear examiner's opinion centres on their ability to determine whether a particular shoe made an impression with greater accuracy than a novice. However, there has been limited research on the expertise of footwear examiners and the accuracy and reproducibility of their decisions. In the current study, we measured the accuracy and consensus of 31 footwear examiners versus a comparison group of 29 novices.

View Article and Find Full Text PDF

Background: Although the ankle strategy is important for achieving frontal plane stability during one-leg stance, previously developed powered ankle-foot orthoses (PAFOs) did not involve ankle strategies because of hardware limitations. Weakness of movement in frontal plane is a factor that deteriorates gait stability and increases fall risk so it should not be overlooked in rehabilitation. Therefore, we used PAFO with subtalar joint for frontal plane movement and tried to confirm that the existence of it is important in balancing through clinical experiments.

View Article and Find Full Text PDF

Background: Excessive plantar pressure leads to increased risk of diabetic foot ulcers. Diabetic peripheral neuropathy (DPN) and peripheral arterial disease (PAD) have been considered to be associated with alterations in gait and plantar pressure in diabetic patients. However, few studies have differentiated the effects with each of them.

View Article and Find Full Text PDF

The high fall rate of the elderly brings enormous challenges to families and the medical system; therefore, early risk assessment and intervention are quite necessary. Compared to other sensor-based technologies, in-shoe plantar pressure sensors, effectiveness and low obtrusiveness are widely used for long-term fall risk assessments because of their portability. While frequently-used bipedal center-of-pressure (COP) features are derived from a pressure sensing platform, they are not suitable for the shoe system or pressure insole owing to the lack of relative position information.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!