A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Reconstruction of complex orbital fracture with titanium implants. | LitMetric

Reconstruction of complex orbital fracture with titanium implants.

Int J Ophthalmol

Department of Ophthalmology, Xiangya Hospital, Central South University, Changsha 410008, Hunan Province, China.

Published: August 2012

Aim: To evaluate the effectiveness and safety of complex orbital fracture reconstruction with titanium implants.

Methods: A retrospective review of 46 patients treated with complex orbital fractures reconstruction using titanium implants from January 2005 to December 2008 was conducted. The following data were recorded: age, gender, mechanism of injury, preoperative and postoperative orbital CT, visual acuity, diplopia, ocular motility and Hertel exophthalmometer.

Results: The most common cause was motor vehicle accident (47.8%), followed by industrial injury (30.4%). All patients had improved appearance after operation and CT scan at one week after operation showed the fracture defects of orbit and neighboring areas had been reconstructed. Forty-six cases had various degrees of enophthalmos before operation. Among them, 32 cases were completely corrected, 11 cases improved obviously and 3 cases had no improvement after operation. Thirty-six patients with visual acuity ≥20/60 revealed diplopia of various degrees, including 26 patients had diplopia in right ahead and/or reading positions. At the sixth month after operation, diplopia disappeared in five patients, 7 patients still had diplopia in right ahead and/or reading positions, 14 patients had diplopia in positions rather than right ahead and reading positions (<20°) and ten patients had diplopia only at peripheral gazing (>20°). All patients had various degrees of ocular motility disorders before operation. At the sixth month after operation, eyeball movement disorder disappeared in 9 patients, 31 patients showed improvement and 6 patients had no improvement. Complications of implant infection, rejection and displacement were not reported after operation.

Conclusion: The application of titanium implants in the repair of complex orbital fractures greatly improves the appearance and functional results, which is a favorable material for plastic surgery of complex orbital fracture.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3428547PMC
http://dx.doi.org/10.3980/j.issn.2222-3959.2012.04.16DOI Listing

Publication Analysis

Top Keywords

complex orbital
20
orbital fracture
12
titanium implants
12
patients diplopia
12
reading positions
12
patients
11
reconstruction titanium
8
orbital fractures
8
visual acuity
8
ocular motility
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!