A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A specific Tween-80-Rhodamine S-MWNTs phosphorescent reagent for the detection of trace calcitonin. | LitMetric

The present study proposed a simple sensitive and specific immunoassay for the quantification of calcitonin (CT) in human serum with water-soluble multi-walled carbon nanotubes (MWNTs). The COOH group of MWNTs could react with the NH group of rhodamine S (Rhod.S) molecules to form Rhod.S-MWNTs, which could emit room temperature phosphorescence (RTP) on acetate cellulose membrane (ACM) and react with Tween-80 to form micellar compound. Tween-80-Rhod.S-MWNTs (TRM), as a phosphorescent labelling reagent, could dramatically enhance the RTP signal of the system. The developed TRM phosphorescent reagent was used to label anti-calcitonin antibody (Ab(CT)) to form the TRM-Ab(CT) labelling product, which could take high specific immunoreaction with CT, and the ΔI(p) (= I(p2)-I(p1), I(p2) and I(p1) were the phosphorescence intensity of the test solution and the blank sample, respectively) of the system was linear to the content of CT. Hence, a new solid substrate room temperature phosphorescence immunoassay (SSRTPIA) was established for the determination of CT in human serum. This sensitive (limit of quantification (LOQ) was 8.0×10(-14) g mL(-1)), accurate, selective and precise method has been applied to determine CT in human serum and predict primary osteoporosis and fractures, with the results in good agreement with those obtained by chemiluminescence immunoassay (CLIA). Simultaneously, the structure of MWNTs was characterized with scanning electron microscopy (SEM) and infrared spectroscopy (IR), and the reaction mechanisms of both labelling Ab(CT) with TRM and SSRTPIA for the determination of trace CT were discussed.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.aca.2012.07.017DOI Listing

Publication Analysis

Top Keywords

human serum
12
phosphorescent reagent
8
room temperature
8
temperature phosphorescence
8
trm phosphorescent
8
specific tween-80-rhodamine
4
tween-80-rhodamine s-mwnts
4
s-mwnts phosphorescent
4
reagent detection
4
detection trace
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!