A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Predictability of the corneal flap creation with the femtosecond laser in LASIK]. | LitMetric

Objective: To observe the predictability of corneal flap creation with the FEMTO LDV femtosecond laser and analyze preliminarily the factors correlating to the thickness and diameter of the flap .

Methods: It was a study of serial cases. 260 eyes of 130 consecutive patients were treated with the FEMTO LDV. The eyes were assigned to two groups according to intended flap thickness, 110 µm (208 eyes) and 90 µm (52 eyes). Intended flap diameter varied from 8.5 to 9.5 mm. Difference analysis of flap diameter and intended diameter as well as flap thickness and intended thickness were made. The data was analyzed with SPSS to sum up a multiple stepwise regression formula that could express their quantitative relationship.

Results: The 90 µm flap group had a average flap thickness of (95.12 ± 7.65) µm, while for the 110 µm group the average flap thickness was (104.81 ± 3.09) µm. The difference between right and left eyes was not statistically significant (t(110 µm) = -1.223, t(90 µm) = -1.343, P > 0.05). Corneal flap thickness was inversely correlated with flap diameter (r(110 µm) = -0.143, r(90 µm) = -0.315, P < 0.05), but was not related to preoperative patient age, corneal thickness, keratometric value K or intraocular pressure (r(110 µm) = -0.160, 0.054, -0.011, -0.363; r(90 µm) = 0.024, 0.074, -0.212, -0.434, all P > 0.05). Corneal flap diameter was positively correlated with preoperative corneal keratometric value K and thickness (P < 0.001, P < 0.05). Multiple stepwise regression analysis showed flap diameter was an influencing factor for flap thickness. Preoperative corneal keratometric value K and thickness were influencing factors for flap diameter.

Conclusions: The LASIK flap creation with the FEMTO LDV laser has relatively good predictability. Flap diameter is an influencing factor for flap thickness.

Download full-text PDF

Source

Publication Analysis

Top Keywords

flap thickness
28
flap diameter
24
flap
19
corneal flap
16
flap creation
12
femto ldv
12
thickness
12
µm
12
femtosecond laser
8
creation femto
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!