Background: Percutaneous vertebroplasty (PVP) has become a popular procedure for painful vertebral osteoporotic fracture (VOF), with immediate pain relief and improved mobility; however, polymethylmethacrylate (PMMA) injected into the vertebral body is not absorbable and little information is available concerning the long-term results. In this retrospective study, we evaluated the long-term clinical results and radiological changes after PVPs for VOFs.
Methods: Fifty-one patients with VOFs were treated by PVPs with PMMA between 2000 and 2004. After > 7 years of follow-up, eight patients had died from causes unrelated to the intervention and 12 patients were lost to follow-up, thus leaving 31 patients available for evaluation with an average length of follow-up of 9.2 years (follow-up rate, 72.1%). Among these 31 patients, the PMMA was injected at 43 levels with a mean volume of 4.3 ml per level (range, 2 - 6 ml). The pain was assessed with a visual analog scale (VAS), and the mobility was graded as walking without difficulty (grade 1), walking with assistance (grade 2), and bedridden (grade 3). Plain radiographs and computed tomography (CT) were obtained and assessed pre-operatively, immediately post-operatively, and after 7 years of follow-up. The PMMA, vertebral height, and Cobb angle were assessed and compared.
Results: All of the patients experienced pain relief and improved mobility after intervention and during the follow-up period. Cement leakage was detected in post-operative CT scans in 9 of 51 patients, but without neurological compromise. For the 31 patients followed up over 7 years, the VAS decreased from 8.3 ± 2.6 pre-operatively, to 2.1 ± 1.6 immediately post-operatively, and 1.0 ± 0.9 at the final follow-up evaluation, with significantly improved mobility. Additional compression fractures occurred at adjacent levels in three patients, and there were no new fractures at the augmented vertebrae. Based on a review of the radiographs, neither loose nor displaced cement was detected. The changes in vertebral height and Cobb angle were not significant. On CT scans, the cement closely contacted or infiltrated the trabecular bone. The boundary between the cement and trabecular bone was indistinct and there was no evident radiolucent gap between the cement and trabecular bone.
Conclusions: At an average follow-up of 9.2 years, PVPs provided sustained pain relief and improved mobility in patients with VOFs. The PMMA injected into the vertebral body combined closely with the host trabecular bone without adverse reactions.
Download full-text PDF |
Source |
---|
Health Place
January 2025
Barcelona Institute for Global Health (ISGlobal), Doctor Aiguader 88, 08003, Barcelona, Spain; Universitat Pompeu Fabra (UPF), Department of Experimental and Health Sciences, Doctor Aiguader 88, 08003, Barcelona, Spain; CIBER Epidemiología y Salud Pública (CIBERESP), Melchor Fernández Almagro, 3-5, 28029, Madrid, Spain. Electronic address:
Background: Urban spaces need to be rethought to address growing health and environmental challenges. Urban density and transport systems contribute significantly to air pollution, negatively impacting public health. Barcelona has begun a transformation by introducing the Superblock model, an urban development with proven health benefits.
View Article and Find Full Text PDFPhysiother Res Int
January 2025
Department of Biomedical Engineering, University of Engineering and Technology (UET) Lahore, Narowal Campus, Narowal, Pakistan.
Background And Purpose: Throwing a baseball involves intense exposure of the arm to high speeds and powerful forces, which contributes to an increasing prevalence of arm injuries among athletes. Traditional rigid exoskeletons and rehabilitation equipment frequently lack portability, safety, ergonomic design, and affordability. Traditional rehabilitation approaches frequently require therapist monitoring, resulting in therapy delays.
View Article and Find Full Text PDFNatl Sci Rev
January 2025
School of Physics, State Key Laboratory of Crystal Materials, Shandong University, Jinan 250100, China.
The incorporation of polymeric insulators has led to notable achievements in the field of organic semiconductors. By altering the blending concentration, polymeric insulators exhibit extensive capabilities in regulating molecular configuration, film crystallinity, and mitigation of defect states. However, current research suggests that the improvement in such physical properties is primarily attributed to the enhancement of thin film morphology, an outcome that seems to be an inevitable consequence of incorporating insulators.
View Article and Find Full Text PDFInt J Stroke
January 2025
School of Health Sciences, The University of Melbourne, Parkville VIC Australia.
Background: Falls are common after stroke and can have serious consequences such as hip fracture. Prior research shows around half of individuals will fall within the 12 months post stroke and these falls are more likely to cause serious injury compared to people without stroke. However, there is limited research on risk factors collected in the immediate post-stroke period that may relate to falls risk.
View Article and Find Full Text PDFClin Rehabil
January 2025
Department of Biomedical Physiology and Kinesiology, Simon Fraser University, Burnaby, BC, Canada.
Objective: Current clinical practice guidelines support structured, progressive protocols for improving walking after stroke. Technology enables monitoring of exercise and therapy intensity, but safety concerns could also be addressed. This study explores functional mobility in post-stroke individuals using wearable technology to quantify movement smoothness-an indicator of safe mobility.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!