Prognostic value of ventricular wall fluorescence during 5-aminolevulinic-guided surgery for glioblastoma.

Acta Neurochir (Wien)

Department of Neurosurgery, Clínica Universidad de Navarra, C/Pio XII 36, 31008, Pamplona, Navarra, Spain.

Published: November 2012

Background: The meaning of the ventricular wall fluorescence during 5-aminolevulinic (5-ALA)-guided surgery in patients with glioblastoma (GBM) is still unknown. The authors studied the association between ventricle fluorescence, clinical outcome and survival, and described the histopathological findings of selective biopsies from the ventricular wall.

Methods: One hundred and forty patients diagnosed of GBM underwent fluorescence-guided surgery (FGS); 65 of them were naive GBM and ventricle fluorescence during surgery was annotated prospectively. Selective biopsies were collected from the ventricular wall when possible. Clinical and radiological data were registered, including age, Karnofsky Performance Scale (KPS) score, presence of hydrocephalus, overall survival (OS), tumour volume and location (periventricular vs non-periventricular) and leptomeningeal dissemination.

Results: During FGS the ventricle wall was opened just when the tumour was periventricular in the preoperative MRI (45 out of 65). In 28 of them (60 %) the fluorescence extended far away from the site of opening, while in 17 it ended just in the few millimetres around the tumour. All four patients who developed hydrocephalus had periventricular tumours and the ventricle wall had been opened during surgery. Statistically significant differences were seen in OS according to periventricular location (15 m vs 33 m, P = 0.008 log rank). However, there was not significant relationship between ventricle fluorescence and hydrocephalus (P = 0.75), nor survival (14 m vs 15.5 m, P = 0.64).

Conclusions: Preoperative MRI predicts if the ventricle will be opened using the 5-ALA fluorescence, according to tumour location. It does not predict, however if the ventricle wall is going to be fluorescent or not. The fluorescence of the ventricle wall is not a predictor for complications or survival. Periventricular tumour location is an independent bad prognostic factor in GBM.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00701-012-1475-1DOI Listing

Publication Analysis

Top Keywords

ventricle wall
16
ventricular wall
12
ventricle fluorescence
12
fluorescence
8
wall fluorescence
8
ventricle
8
selective biopsies
8
wall opened
8
preoperative mri
8
tumour location
8

Similar Publications

Simulating the cardiac valves is one of the most complex tasks in cardiovascular modeling. As fluid-structure interaction simulations are highly computationally demanding, machine-learning techniques can be considered a good alternative. Nevertheless, it is necessary to design many aortic valve geometries to generate a training set.

View Article and Find Full Text PDF

Background: A patient with acute myeloid leukemia (AML) presented with a cardiac mass of unknown nature. This case underscores the importance of careful monitoring and a multidisciplinary approach in managing and differentiation of rare cardiac complications in leukemia patients. It aims to improve diagnostic accuracy and therapeutic outcomes in similar challenging scenarios.

View Article and Find Full Text PDF

Background: Left ventricular unloading is needed in patients on extracorporeal life support (ECLS) with severely impaired left ventricular contractility to avoid stasis and pulmonary congestion, and to promote LV recovery. The presence of thrombi in the LV precludes the use of conventional active unloading methods such as transaortic microaxial pumps or apical LV vents. We describe placement of a vent cannula via the left atrial appendage (LAA) as a useful bailout option.

View Article and Find Full Text PDF

Background: Penetrating cardiac trauma is an entity with high pre and intrahospital mortality due to complications such as cardiac tamponade and massive hemothorax. A ventricular septal defect (VSD) occurs in 1-5% of cases and can present early or late. The management strategy for VSD resulting from penetrating cardiac trauma is uncertain.

View Article and Find Full Text PDF

Introduction: The docking button of the Aveir leadless pacemaker (LP) is occasionally difficult to access due to its inappropriate position in the right ventricle (RV).

Methods And Results: We report a case where the Aveir LP was successfully retrieved by releasing the wedged docking button in the inferior wall of the RV using a loop wire technique.

Conclusion: The loop wire technique may be useful to change the position of the Aveir LP.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!