Direct 4-D PET list mode parametric reconstruction with a novel EM algorithm.

IEEE Trans Med Imaging

PET Center, Department of Diagnostic Radiology, Yale University, New Haven, CT 06520 USA.

Published: December 2012

The production of images of kinetic parameters is often the ultimate goal of positron emission tomography (PET) imaging. The indirect method of PET parametric imaging, also called the frame-based method (FM), is performed by fitting the time-activity curve (TAC) for each voxel with an appropriate compartment model after image reconstruction. The indirect method is simple and easily implemented, however, it usually leads to some loss of accuracy or precision, due to the use of two separate steps. This paper presents a direct 4-D method for producing 3-D images of kinetic parameters from list mode PET data. In this application, the TAC for each voxel is described by a one-tissue compartment model (1T). Extending previous EM algorithms, a new spatiotemporal complete data space was introduced to optimize the maximum likelihood function. This leads to a straightforward closed-form parametric image update equation. This method was implemented by extending the current list mode platform MOLAR to produce a parametric algorithm PMOLAR-1T. Using an ordered subset approach, qualitative and quantitative evaluations were performed using 2-D (x, t) and 4-D (x, y, z, t) simulated list mode data based on brain receptor tracers and also with a human brain study. Comparisons with the indirect method showed that the proposed direct method can lead to accurate estimation of the parametric image values with reduced variance, especially at low count levels. In the 2-D test, the direct method showed similar bias to the frame-based method but with variance reduction of 23%-60%. In the 4-D test, bias values of both methods were no more than 4% and the direct method had lower variability (coefficient of variation reduction of 0%-64% compared to the frame-based method) at the normal count level. The direct method had a larger reduction in variability (27%-81%) and lower bias (1%-5% for 4-D and 1%-19% for FM) at low count levels. The results in the human brain study are similar with PMOLAR-1T showing lower noise than FM.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3660152PMC
http://dx.doi.org/10.1109/TMI.2012.2212451DOI Listing

Publication Analysis

Top Keywords

list mode
16
direct method
16
method
12
indirect method
12
frame-based method
12
direct 4-d
8
images kinetic
8
kinetic parameters
8
tac voxel
8
compartment model
8

Similar Publications

Objectives: This study aimed to evaluate the quality and associated quantitative values of bone single-photon emission computed tomography (SPECT) with and without SwiftScan using a semiconductor camera equipped with a cadmium-zinc-telluride detector.

Methods: Ten patients with bone metastases from prostate cancer who underwent list-mode SPECT/computed tomography using a whole-body semiconductor camera participated in this study. A total of 130 metastatic lesions from 10 patients were analyzed.

View Article and Find Full Text PDF

Ultra-fast [F]florbetapir PET imaging using the uMI Panorama PET/CT system.

EJNMMI Phys

December 2024

Department of Nuclear Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Center for Rare Diseases Research, Beijing Key Laboratory of Molecular Targeted Diagnosis and Therapy in Nuclear Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, 1# Shuaifuyuan, Dongcheng District, Beijing, 100730, China.

Background: There is a need for faster amyloid PET scans to reduce patients' discomfort, minimize movement artifacts, and increase throughput. The recently introduced uMI Panorama PET/CT system featuring enhanced spatial resolution and sub-200ps TOF offers the potential for shorter scan duration without sacrificing image quality or efficacy to detect Aβ deposition. The study aims to establish a faster acquisition protocol for [F]florbetapir PET imaging using digital PET/CT scanner uMI Panorama, while ensuring adequate image quality and amyloid-β (Aβ) detectability comparable to the standard 10-minute scan.

View Article and Find Full Text PDF

Deep learning-based low count whole-body positron emission tomography denoising incorporating computed tomography priors.

Quant Imaging Med Surg

December 2024

Biomedical Imaging Laboratory (BIG), Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Macau, China.

Background: Deep-learning-based denoising improves image quality and quantification accuracy for low count (LC) positron emission tomography (PET). Conventional deep-learning-based denoising methods only require single LC PET image input. This study aims to propose a deep-learning-based LC PET denoising method incorporating computed tomography (CT) priors to further reduce the dose level.

View Article and Find Full Text PDF

Introduction: Fertility patients increasingly use web-based and mobile-based apps to access psychosocial care. These digital tools may be a helpful alternative to traditional psychological interventions. Developing and evaluating patient-centred e-mental health tools rooted in evidence-based interventions is a priority.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!