A method to localize RF B₁ field in high-field magnetic resonance imaging systems.

IEEE Trans Biomed Eng

Department of Electrical and Computer Engineering and the Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, MN 55455, USA.

Published: December 2012

In high-field magnetic resonance imaging (MRI) systems, B₀ fields of 7 and 9.4 T, the RF field shows greater inhomogeneity compared to clinical MRI systems with B₀ fields of 1.5 and 3.0 T. In multichannel RF coils, the magnitude and phase of the input to each coil element can be controlled independently to reduce the nonuniformity of the RF field. The convex optimization technique has been used to obtain the optimum excitation parameters with iterative solutions for homogeneity in a selected region of interest. The pseudoinverse method has also been used to find a solution. The simulation results for 9.4- and 7-T MRI systems are discussed in detail for the head model. Variation of the simulation results in a 9.4-T system with the number of RF coil elements for different positions of the regions of interest in a spherical phantom are also discussed. Experimental results were obtained in a phantom in the 9.4-T system and are compared to the simulation results and the specific absorption rate has been evaluated.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4041104PMC
http://dx.doi.org/10.1109/TBME.2012.2208965DOI Listing

Publication Analysis

Top Keywords

mri systems
12
high-field magnetic
8
magnetic resonance
8
resonance imaging
8
systems b₀
8
b₀ fields
8
94-t system
8
method localize
4
localize b₁
4
b₁ field
4

Similar Publications

Lipid nanoparticles formed with copolymers are a new and increasingly powerful tool for studying membrane proteins, but the extent to which these systems affect the physical properties of the membrane is not completely understood. This is critical to understanding the caveats of these new systems and screening for structural and functional artifacts that might be caused in the membrane proteins they are used to study. To better understand these potential effects, the fluid properties of dipalmitoylphosphatidylcholine lipid bilayers were examined by electron paramagnetic resonance (EPR) spectroscopy with spin-labeled reporter lipids in either liposomes or incorporated into nanoparticles with the copolymers diisobutylene-maleic acid or styrene maleic acid.

View Article and Find Full Text PDF

Hypereosinophilic syndrome (HES) is traditionally described as chronic peripheral eosinophilia with involvement of various organs and systems, including the heart and nervous system. In this report, we describe cardiac involvement and border zone stroke in a patient with idiopathic HES. A 37-year-old woman presented with sudden right-sided weakness and slurred speech, which began four days before admission, accompanied by palpitations, retrosternal exertional chest discomfort, dry cough, and progressive shortness of breath over approximately two months.

View Article and Find Full Text PDF

Background: Previous studies have shown that people with multiple sclerosis (MS) had frequent healthcare visits up to 10 years before being diagnosed but with no information from magnetic resonance imaging (MRI) scans of the connection with the radiologically isolated syndrome (RIS).

Objective: To analyze healthcare use 3 years before the RIS diagnosis.

Methods: We examined healthcare usage before the first scan in RIS cases from 2010 to 2019.

View Article and Find Full Text PDF

Node Reporting and Data System 1.0 (Node-RADS) for the Assessment of Oncological Patients' Lymph Nodes in Clinical Imaging.

J Clin Med

January 2025

Radiology, Multizonal Unit of Rovereto and Arco, APSS Provincia Autonoma Di Trento, 38123 Trento, Italy.

The assessment of lymph node (LN) involvement with clinical imaging is a key factor in cancer staging. Node Reporting and Data System 1.0 (Node-RADS) was introduced in 2021 as a new system specifically tailored for classifying and reporting LNs on computed tomography (CT) and magnetic resonance imaging scans.

View Article and Find Full Text PDF

Olfactory dysfunction (OD) is an underestimated symptom in multiple sclerosis (MS). Multiple factors may play a role in the OD reported by MS patients, such as ongoing inflammation in the central nervous system (CNS), damage to the olfactory bulbs due to demyelination, and the presence of plaques in brain areas associated with the olfactory system. Indeed, neuroimaging studies in MS have shown a clear association of the OD with the number and activity of MS-related plaques in frontal and temporal brain regions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!