Background: Transcatheter aortic valve implantation (TAVI) has emerged as an alternative treatment for high-risk and inoperable patients. Advanced multimodality imaging, including computed tomography (CT), plays a key role for optimized planning of TAVI.
Methods: Forty-nine patients (25 women; age, 82.3±8.8 year) with severe aortic stenosis scheduled for TAVI were examined with 128-slice high-pitch dual-source prospective aortoiliac CT angiography (CTA). The 3-coronary-sinus-alignment (3-CSA) plane, comprising left and right anterior oblique and craniocaudal projection, was defined from three-dimensional volume-rendered technique data sets and compared with the intraoperative angiographic plane (deployment plane) used for device implantation. A tolerance level of ±5-degree deviation was acceptable. Volume of intraoperative iodine contrast agent was compared before and after the implementation of the 3-CSA plane estimation by CT.
Results: All 49 patients underwent TAVI, during which 6 CoreValves (Medtronic, Minneapolis, MN) and 43 Sapien valves (Edwards Lifesciences, Irvine, CA) were successfully implanted using transapical (n=29), transfemoral (n=17), and transaxillary access (n=4). No severe complications occurred. In 47 patients (96%), CTA correctly predicted the 3-CSA plane used for device implantation. Mean left anterior oblique by CTA was 5.3±6.5 degrees and craniocaudal was -1.3±10.1 degrees. Mean left anterior oblique deviation between CTA and the intraoperative projection was 2.1±2.7 degrees and craniocaudal was 1.7±3.0 degrees. Ostium heights of the right and left coronary arteries were 12±1.9 and 12.9±3.3 mm. No over-stenting occurred in left coronary artery ostia of 8 mm or more. Contrast volume was reduced from 81.8±25.6 to 59.4±40.2 mL (p=0.05) when using 3-CSA plane estimation by CT for final prosthesis implantation plane.
Conclusions: Aortoiliac high-pitch 128-slice dual-source CT contributes to TAVI planning, including reliable prediction of the 3-CSA valve deployment plane, which saves contrast volume during the procedure and may facilitate correct valve placement.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.athoracsur.2012.06.044 | DOI Listing |
PLoS One
November 2023
Department of Emergency Medicine, King Saud University, Riyadh, Saudi Arabia.
Oblique orientation of vocal cord demands strict compliance, by technicians and clinicians, to the recommended parallel plane CT scan of larynx. Repercussions of non-compliance has never been investigated before. We aimed to observe influence of non-parallel vocal cord plane CT scan on qualitative and quantitative glottic parameters, keeping parallel plane CT as a standard for comparison.
View Article and Find Full Text PDFAnn Thorac Surg
December 2012
Department of Radiology, Innsbruck Medical University, Innsbruck, Austria.
Background: Transcatheter aortic valve implantation (TAVI) has emerged as an alternative treatment for high-risk and inoperable patients. Advanced multimodality imaging, including computed tomography (CT), plays a key role for optimized planning of TAVI.
Methods: Forty-nine patients (25 women; age, 82.