A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Purification and labeling strategies for (68)Ga from (68)Ge/ (68)Ga generator eluate. | LitMetric

Purification and labeling strategies for (68)Ga from (68)Ge/ (68)Ga generator eluate.

Recent Results Cancer Res

Department of Nuclear Medicine, Centre for PETCT, Bad Berka, Germany.

Published: June 2013

For successful labeling, (68)Ge/(68)Ga generator eluate has to be concentrated (from 10 mL or more to less than 1 mL) and to be purified of metallic impurities, especially Fe(III), and (68)Ge breakthrough. Anionic, cationic and fractional elution methods are well known. We describe two new methods: (1) a combined cationic-anionic purification and (2) an easy-to-use and reliable cationic purification with NaCl solution. Using the first method, (68)Ga from 10 mL generator eluate was collected on a SCX cartridge, then eluted with 1.0 mL 5.5 M HCl directly on an anion exchanger (30 mg AG1X8). After drying with a stream of helium, (68)Ga was eluted with 0.4 mL water into the reaction vial. We provide as an example labeling of BPAMD. Using the second method, (68)Ga from 10 mL generator eluate was collected on a SCX cartridge, then eluted with a hydrochloric solution of sodium chloride (0.5 mL 5 M NaCl, 12.5 μL 5.5 M HCl) into the reaction vial, containing 40 μg DOTATOC and 0.5 mL 1 M ammonium acetate buffer pH 4.5. After heating for 7 min at 90°C, the reaction was finished. Radiochemical purity was higher than 95% without further purification. No (68)Ge breakthrough was found in the final product.

Download full-text PDF

Source
http://dx.doi.org/10.1007/978-3-642-27994-2_5DOI Listing

Publication Analysis

Top Keywords

generator eluate
16
68ge breakthrough
8
method 68ga
8
68ga 10 ml
8
10 ml generator
8
eluate collected
8
collected scx
8
scx cartridge
8
cartridge eluted
8
55 m hcl
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!