Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: It is accepted that there is a severe risk of dural puncture in epidural anesthesia. Of major concern to anesthesiologists is unintentional spinal block. Reliable identification of cerebrospinal fluid (CSF) from the aspirate is crucial for safe epidural anesthesia. The aim of this study was to determine whether prostaglandin D2 could be clinically used as a marker for the detection of CSF traces.
Methods: After obtaining Institutional Review Board approval and patient consent, CSF was obtained from patients undergoing spinal anesthesia, and blood, urine, and saliva were obtained from normal subjects and analyzed for prostaglandin D2 (PGD). CSF (n=5) samples were diluted with local anesthetic (bupivacaine), normal saline and blood in the ratios of 1:5 and 1:10. PGD levels in the CSF samples were analyzed with a PGD-Methoxime (MOX) EIA Kit (Cayman Chemicals, MI). This assay is based on the conversion of PGD to a stable derivative, which is analyzed with antiserum specific for PGD-MOX.
Results: Different concentrations of pure PGD-MOX conjugate were analyzed by EIA and a standard curve was derived. PGD levels in CSF and CSF with diluents were determined and the values were extrapolated onto the standard curve. Our results show a well-defined correlation for the presence of PGD both in straight CSF samples and in diluted CSF (dilution factor of 1:5 and 1:10).
Conclusion: Prostaglandin D2 was reliably identified in CSF by enzyme-linked immunosorbent assay when diluted with local anesthetic, saline, and serum, and can be used as a marker to identify the presence of CSF in epidural aspirates.