Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: The purpose of this study was to compare the differences in kinetic assessments of lesions at breast MRI performed with higher and lower temporal resolution.
Materials And Methods: All consecutively evaluated BI-RADS category 4, 5, and 6 lesions imaged with breast MRI and pathologically confirmed from October 2005 to August 2009 were identified. Patients underwent MRI with one of two dynamic contrast-enhanced protocols: one with 90-second (October 2005-June 2006) and another with 180-second (July 2006-August 2009) temporal resolution. Studies were processed with a computer-aided evaluation system with initial and delayed contrast-enhanced time points with the k-space centered 90 and 450 seconds after contrast injection. Initial-phase peak enhancement, delayed-phase predominant curve type, and worst curve type were recorded and compared for benign and malignant lesions across protocols.
Results: The analysis set comprised 993 lesions: 145 imaged with the 90-second acquisition (17 benign, 28 ductal carcinoma in situ [DCIS], 100 invasive cancer) and 848 imaged with the 180-second acquisition (212 benign, 145 DCIS, 491 invasive cancer). Peak enhancement was significantly higher for both benign lesions (p = 0.01) and invasive cancers (p = 0.0008) with the 180-second protocol. Peak enhancement of DCIS was similar in the two protocols (p = 0.88). Delayed-phase kinetics were similar for the two protocols for both benign and malignant lesions when defined by predominant or worst curve type.
Conclusion: Although it has lower temporal resolution, a 180-second acquisition may be preferable because it allows higher spatial resolution and captures higher initial-phase peak enhancement without loss of delayed-phase kinetic information.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.2214/AJR.11.7836 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!