A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Prevention of biofilm formation on urinary catheters: comparison of the sparfloxacin-treated long-term antimicrobial catheters with silver-coated ones. | LitMetric

Urinary catheters are widely used for hospitalized patients and are often associated with high risk of urinary tract infection. The agar and broth diffusion tests, visual TTC (triphenyltetrazolium chloride) method, and confocal scanning laser microscopic (CSLM) observations have shown highly satisfactory antimicrobial and antibiofilm activity of the novel sparfoxacin (SPA)-treated urinary catheters compared with the controversial effectiveness of silver(Ag)-coated catheters against a background of untreated catheters used as controls. SPA-treated catheters were significantly less likely to become colonized (less than 0.01%; inner and outer surfaces against Escherichia coli and Staphylococcus aureus) than both silver-coated (from 0.01% to 39.3 %; outer surface against E. coli and inner surface against S. aureus, resp.) and untreated catheters (from 88.43% to 99.72%; outer and inner surfaces, resp., against S. aureus), and maintained their broad spectrum of antimicrobial and antibiofilm activity during storage for at least 6 months.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jbm.b.32755DOI Listing

Publication Analysis

Top Keywords

urinary catheters
12
catheters
8
antimicrobial antibiofilm
8
antibiofilm activity
8
untreated catheters
8
prevention biofilm
4
biofilm formation
4
urinary
4
formation urinary
4
catheters comparison
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!