Propofol is a widely used, potent intravenous anesthetic for ambulatory anesthesia and long-term sedation. The target steady state concentration of propofol in blood is 0.25-10 μg/mL (1-60 μM). Although propofol can be oxidized electrochemically, monitoring its concentration in biological matrixes is very challenging due to (i) low therapeutic concentration, (ii) high concentrations of easily oxidizable interfering compounds in the sample, and (iii) fouling of the working electrode. In this work we report the performance characteristics of an organic film coated glassy carbon (GC) electrode for continuous monitoring of propofol. The organic film (a plasticized PVC membrane) improved the detection limit and the selectivity of the voltammetric sensor due to the large difference in hydrophobicity between the analyte (propofol) and interfering compounds of the sample, e.g., ascorbic acid (AA) or p-acetamidophenol (APAP). Furthermore, the membrane coating prevented electrode fouling and served as a protective barrier against electrode passivation by proteins. Studies revealed that sensitivity and selectivity of the voltammetric method is greatly influenced by the composition of the PVC membrane. The detection limit of the membrane-coated sensor for propofol in PBS is reported as 0.03 ± 0.01 μM. In serum-like electrolyte solutions containing physiologically relevant levels of albumin (5%) and 3 mM AA and 1 mM APAP as interfering agents, the detection limit was 0.5 ± 0.4 μM. Both values are below the target concentrations used clinically during anesthesia or sedation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/ac3006878 | DOI Listing |
Plant Dis
January 2025
USDA-ARS North Central Agricultural Research Laboratory, Brookings, South Dakota, United States;
Soilborne diseases are persistent problems in soybean production. Long-term crop rotation can contribute to soilborne disease management. However, the response of soilborne pathogens to crop rotation is inconsistent, and rotation efficacy is highly variable.
View Article and Find Full Text PDFAnal Chem
January 2025
Instrumental Analytical Chemistry, University of Duisburg-Essen, Universitätsstraße 5, 45141 Essen, Germany.
Compound-specific stable isotope analysis (CSIA) using liquid chromatography-isotope ratio mass spectrometry (LC-IRMS) is a powerful tool for determining the isotopic composition of carbon in analytes from complex mixtures. However, LC-IRMS methods are constrained to fully aqueous eluents. Previous efforts to overcome this limitation were unsuccessful, as the use of organic eluents in LC-IRMS was deemed impossible.
View Article and Find Full Text PDFJ Agric Food Chem
January 2025
College of Chemistry and Chemical Engineering, Jishou University, Jishou, Hunan 416000, P. R. China.
Detecting β-lactoglobulin (β-Lg) with high sensitivity and selectivity is an urgent requirement due to nearly 80% of milk anaphylaxis, such as respiratory tract, skin urticaria, and gastrointestinal disorders, being caused by β-Lg. An ultrasensitive β-Lg electrochemical aptasensor utilizing core-satellite gold nanoparticle@silver nanocluster (AuNPs@AgNCs) nanohybrids as electrocatalysts was developed. First, β-Lg aptamer was anchored on gold electrodes and AuNPs to obtain high selectivity.
View Article and Find Full Text PDFEmerg Microbes Infect
January 2025
State Key Laboratory of Experimental Hematology, Department of Physiology and Pathophysiology, Tianjin Medical University, Heping, Tianjin, 300070 China.
The monkeypox (MPXV) outbreak in 2022 is more prevalent among individuals with human immunodeficiency virus (HIV). While it is plausible that HIV-induced immunosuppression could result in a more severe progression, the exact mechanisms remain undetermined. To better understand the immunopathology of MPXV in patients with and without HIV infection, we employed single-cell RNA sequencing (scRNA-seq) to analyze peripheral blood mononuclear cells (PBMCs) from 6 patients hospitalized for MPXV, 3 of whom had HIV infection (HIV antibody positive & HIV RNA level below the detection limit), and 3 patients only infected with MPXV (HIV-).
View Article and Find Full Text PDFAnal Chem
January 2025
Hunan Provincial Key Laboratory of Micro & Nano Materials Interface Science, College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, China.
Microelectrodes offer exceptional sensitivity, rapid response, and versatility, making them ideal for real-time detection and monitoring applications. Photoelectrochemical (PEC) sensors have shown great value in many fields due to their high sensitivity, fast response, and ease of operation. Nevertheless, conventional PEC sensing relies on cumbersome external light sources and bulky electrodes, hindering its miniaturization and implantation, thereby limiting its application in real-time disease monitoring.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!