Single-detector polarization-sensitive optical coherence tomography for assessment of rotator cuff tendon integrity.

Am J Orthop (Belle Mead NJ)

Center for Optical Coherence Tomography and Optical Physics, Department of Orthopedic Surgery, Brigham and Women's Hospital, Boston, Massachusetts 02115, USA.

Published: August 2012

This preliminary study assessed trimmed supraspinatus tendons from rotator cuff repairs (RCRs) to compare the samples' surgically cut ends and torn ends with histopathology and polarization-sensitive optical coherence tomography (PS-OCT) imaging. PS-OCT can be used to assess collagen content and organization in birefringent tissue and shows promise in RCR. The data were compared to determine correlations between luminosity measured from histopathology and PS-OCT. Bivariate plots and a simple regression were performed to assess the linearity of the 2 groups, with a predictive value of less than .05 showing significant correlation. Approximately 50% of the visually inspected supraspinatus tendons acceptable for RCR exhibited collagen depletion when examined by histopathology, compared with PS-OCT. Because a strong correlation in collagen concentrations existed between histopathology and PS-OCT polarized back-reflection intensity, this study established the potential of PS-OCT for clinical use in the assessment of collagen content and organization to improving outcomes in RCR.

Download full-text PDF

Source

Publication Analysis

Top Keywords

polarization-sensitive optical
8
optical coherence
8
coherence tomography
8
rotator cuff
8
supraspinatus tendons
8
collagen content
8
content organization
8
histopathology ps-oct
8
ps-oct
6
single-detector polarization-sensitive
4

Similar Publications

Significance: A data-based calibration method with enhanced depolarization contrast in polarization-sensitive optical coherence tomography (PS-OCT) was developed and demonstrated effective for detecting melanin content in the eye.

Aim: We aim to mitigate the dependence between the measured depolarization metric and the intensity signal-to-noise ratio (SNR) for improved visualization of depolarizing tissues, especially in low SNR regions, and to demonstrate the enhanced depolarization contrast to evaluate melanin presence.

Approach: A function for calibrating the depolarization metric was experimentally derived from the young albino guinea pig, assuming depolarization free in the retina.

View Article and Find Full Text PDF

Broadband detection technology is crucial in the fields of astronomy and environmental surveying. Two dimensional (2D) materials have emerged as promising candidates for next-generation broadband photodetectors with the characteristics of high integration, multi-dimensional sensing, and low power consumption. Among these, 2D tellurium (Te) is particularly noteworthy due to its excellent mobility, tunable bandgap, and air stability.

View Article and Find Full Text PDF

Transition metal dichalcogenides (TMDs), such as tungsten diselenide (WSe), are expected to be used in next-generation optoelectronic devices due to their unique properties. In this study, we developed a simple method of using ethanol to scroll monolayer WSe nanosheets into nanoscrolls. These nanoscrolls have a quasi-one-dimensional structure, which enhances their electronic and optical properties.

View Article and Find Full Text PDF

Imaging depth-resolved birefringence and optic axis orientation with polarization sensitive optical coherence tomography (PS-OCT) unveils details of tissue structure and organization that can be of high pathophysiologic, mechanistic, and diagnostic value. For catheter-based PS-OCT, the dynamic rotation of the fiber optic probe, in addition to the polarization effects of the system components, complicates the reliable and robust reconstruction of the sample's optic axis orientation. Addressing this issue, we present a new method for the reconstruction of absolute depth-resolved optic axis orientation in catheter-based PS-OCT by using the intrinsic retardance of the protecting catheter sheath as a stable guide star signal.

View Article and Find Full Text PDF

Non-Hermitian systems can be tuned to exhibit exceptional points, where both eigenvalues and eigenstates coalesce concurrently. The inherent adaptability of photonic non-Hermitian systems in configuring gain and loss has allowed us to observe a plethora of counterintuitive phenomena, largely as a consequence of the eigenspace reduction at these exceptional points. In this work, we propose a non-Hermitian metasurface that, through the incorporation of gain, enables complete asymmetric polarization conversion at an exceptional point with a zero eigenvalue.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!