A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Desorption ElectroSpray Ionization - Orbitrap Mass Spectrometry of synthetic polymers and copolymers. | LitMetric

Desorption ElectroSpray Ionization - Orbitrap Mass Spectrometry of synthetic polymers and copolymers.

J Mass Spectrom

Université d'Evry val d'Essonne, Laboratoire Analyse et Modélisation pour la Biologie et l'Environnement, (CNRS UMR 8587/CEA), Bâtiment Maupertuis, Bd. François Mitterrand, 91025, Evry, France.

Published: August 2012

AI Article Synopsis

  • Desorption ElectroSpray Ionization (DESI) combined with Orbitrap Mass Spectrometry was tested for analyzing various synthetic polymers and copolymers, achieving good signal stability and sensitivity.* -
  • The method effectively characterized polymers with molecular weights ranging from 500 g/mol to over 20,000 g/mol, using a water/methanol mix as a spray solvent alongside sodium salt.* -
  • A deconvolution software helped in quickly determining polymer characteristics like M(n), M(w), and PDI values, and analysis results were compared to more traditional techniques like matrix-assisted laser desorption/ionization and gel permeation chromatography.*

Article Abstract

Desorption ElectroSpray Ionization (DESI) - Orbitrap Mass Spectrometry (MS) was evaluated as a new tool for the characterization of various industrial synthetic polymers (poly(ethylene glycol), poly(propylene glycol), poly(methylmethacrylate), poly(dimethylsiloxane)) and copolymers, with masses ranging from 500 g.mol(-1) up to more than 20 000 g.mol(-1) . Satisfying results in terms of signal stability and sensitivity were obtained from hydrophobic surfaces (HTC Prosolia) with a mixture water/methanol (10/90) as spray solvent in the presence of sodium salt. Taking into account the formation of multiplied charged species by DESI-MS, a strategy based on the use of a deconvolution software followed by the automatic assignment of the ions was described allowing the rapid determination of M(n) , M(w) and PDI values. DESI-Orbitrap MS results were compared to those obtained from matrix-assisted laser desorption/ionization- time-of-flight MS and gel permeation chromatography. An application of DESI-Orbitrap MS for the detection and identification of polymers directly from cosmetics was described.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jms.3057DOI Listing

Publication Analysis

Top Keywords

desorption electrospray
8
electrospray ionization
8
orbitrap mass
8
mass spectrometry
8
synthetic polymers
8
ionization orbitrap
4
spectrometry synthetic
4
polymers copolymers
4
copolymers desorption
4
ionization desi
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!