Background And Objective: To describe 'radiation-first' combination treatment with a non-invasive, low-voltage x-ray irradiation system followed by as needed ranibizumab for neovascular age-related macular degeneration (AMD).
Study Design And Methods: Phase I study of non-invasive, low-voltage 16 Gy x-ray irradiation delivered in three beams via the inferior pars plana in patients with active neovascular AMD. Ranibizumab was administered as needed per protocol. Patients were followed monthly for safety and efficacy over 12 months.
Results: 13 patients were enrolled and completed 12 months follow-up. Safety was good with no serious ocular/non-ocular adverse events or radiation-related ocular complications. 11 patients lost <15 Early Treatment of Diabetic Retinopathy Study (ETDRS) letters, seven gained ≥0 ETDRS letters and 0 gained ≥15 ETDRS letters. Patients received a total of 31 subsequent ranibizumab injections (of possible 156) over the 12 months following x-ray irradiation. Mean time to first injection was 3.9 months. One patient received no ranibizumab injections, three patients received one injection, four patients received two injections, and five patients received three or more injections.
Conclusions: After 12 months, non-invasive, low-voltage x-ray irradiation with as needed ranibizumab rescue therapy demonstrated good safety with a visual acuity stabilising effect and reduction in retinal thickness in patients with neovascular AMD.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1136/bjophthalmol-2011-301222 | DOI Listing |
Langmuir
January 2025
Information Device Science Laboratory, Division of Materials Science, Nara Institute of Science and Technology, Ikoma City, Nara 630-0192, Japan.
Front Cardiovasc Med
December 2024
National Key Laboratory for Innovation and Transformation of Luobing Theory, Jinan, China.
Background: Cardiac amyloidosis (CA) is a challenging diagnosis, particularly when the classic signs, such as increased wall thickness in a non-dilated left ventricle (LV), are absent. This makes the diagnosis more difficult in patients with normal LV wall thickness. We present a case of CA without increased wall thickness and without the characteristic granular sparkling echotexture in a non-dilated LV.
View Article and Find Full Text PDFNat Commun
November 2024
Hefei National Research Center for Physical Sciences at the Microscale, University of Science and Technology of China, Hefei, Anhui, 230026, China.
The thickness of X-ray detectors needs to reach hundreds of micrometers to absorb X-ray, and therefore, high voltages over tens or hundreds of volts should be applied to extract X-ray-generated carriers. Here, we propose a bulk Schottky junction for X-ray detection using interpenetrated macroporous-carbon electrodes and metal-halide perovskite networks. The X-ray-generated holes are extracted by the macroporous-carbon electrodes under the built-in electric field, while the electrons in the perovskite phase result in a high gain effect.
View Article and Find Full Text PDFJ Am Chem Soc
December 2024
State Key Laboratory of Material Processing and Die & Mould Technology, School of Materials Science and Engineering, Huazhong University of Science and Technology, Wuhan, Hubei 430074, China.
Nanoscale
December 2024
Departments of Chemistry and Departments of Medical Imaging and Oncology, University of Western Ontario, University of Western Ontario, Centre, 1151 Richmond St, London, ON, N6A 3K7, Canada.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!