This report describes the assessment of three specific safety-related specifications in the consideration of an alternate oxygenator; first the grip strength relationship between various oxygenator connectors and SMARxT tubing, second, the grip strength of various biopassive tubings and an isolated SMARxT connector, and finally, the accuracy of the arterial outlet temperature measurement. Grip strength experiments for the connections between the SMARxT tubing and the venous reservoir outlet and the oxygenator venous inlet and oxygenator arterial outlet of the Medtronic Affinity, Sorin Synthesis, Sorin Primox, and Terumo Capiox RX25 oxygenators were performed. In addition we compared the grip strength of polyvinyl chloride, Physio, Trillium, Carmeda, X-Coating, and SMARxT tubing. The accuracy of the integrated arterial outlet temperature probes was determined by comparing the temperatures measured by the integrated probe with a precision reference thermometer. Connector grip strength comparisons for the evaluation oxygenators with SMARxT tubing showed significant variation between oxygenators and connections (p = .02). Evaluation of the arterial outlet showed significant variation between evaluation oxygenators, while at the venous reservoir outlet and oxygenator inlet, there were no significant differences. Grip strength comparison data for the various tubing types demonstrated a main effect for tubing type F(5, 18) = 8.01, p = .002, eta(p)(2) = .77. Temperature accuracy measurements demonstrated that all oxygenators overread the arterial outlet temperature at 15 degrees C, whilst at temperatures > or = 25 degrees C, all oxygenators underread the arterial outlet temperature. The integrity of SMARxT tubing connection is influenced by the connector type, and may decline over time, highlighting the importance to not consider interchanging components of the bypass circuit as inconsequential.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4557451PMC

Publication Analysis

Top Keywords

grip strength
28
arterial outlet
24
smarxt tubing
20
outlet temperature
16
temperature measurement
8
outlet
8
venous reservoir
8
reservoir outlet
8
outlet oxygenator
8
evaluation oxygenators
8

Similar Publications

Body composition is a determining factor in the physical performance of cyclists, directly influencing efficiency and power during competitions. Understanding these aspects can help optimize training and maximize results. This study aimed to analyze the influence of body composition on physical performance in mountain bike athletes.

View Article and Find Full Text PDF

Association Between Handgrip Strength and Muscle Mass in Children 6 to 10 Years Old.

Clin Nutr ESPEN

January 2025

Brigham Young University, Nutrition, Dietetics, and Food Science Department, Provo, Utah 84602. Electronic address:

Background And Aims: Sarcopenia, defined as a muscle mass loss and function, is increasingly recognized in pediatric populations, particularly in childhood obesity. Therefore, it is necessary to have measurements that can distinguish between muscle and fat mass. Methods of body composition such as Dual Energy X-ray Absorptiometry (DEXA) provide accurate assessments of body composition, but they are resource-intensive and impractical for routine monitoring in clinical or community settings.

View Article and Find Full Text PDF

Objectives: There are no studies examining the prevalence of social frailty and associated factors in low- and middle-income countries. This study aimed to assess the prevalence of social frailty and identify the contributing factors among older adults in Türkiye.

Methods: This cross-sectional study included 570 participants aged 65 and older, all outpatients at a geriatric clinic.

View Article and Find Full Text PDF

Piezo-Capacitive Flexible Pressure Sensor with Magnetically Self-Assembled Microneedle Array.

ACS Sens

January 2025

CAS Key Laboratory of Magnetic Materials and Devices, Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo 315201, P. R. China.

Flexible pressure sensors are pivotal in advancing artificial intelligence, the Internet of Things (IoT), and wearable technologies. While microstructuring the functional layer of these sensors effectively enhances their performance, current fabrication methods often require complex equipment and time-consuming processes. Herein, we present a novel magnetization-induced self-assembly method to develop a magnetically grown microneedle array as a dielectric layer for flexible capacitive pressure sensors.

View Article and Find Full Text PDF

Purpose: Prosthetic replacement of the fragmented, collapsed and unreconstructable lunate is a treatment option in Kienbock's disease. The objective of this study is to assess the effectiveness, safety and outcomes of prosthetic lunate arthroplasty for the treatment of Kienbock's disease.

Methods: We conducted a PRISMA-P compliant systematic review PROSPERO (CRD 42021283996) searching Cochrane, Medline, PubMed and Embase databases for the outcomes of prosthetic lunate arthroplasty.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!