A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Characteristics of diffusion-weighted stimulated echo pulse sequence in human skeletal muscle. | LitMetric

The aim of our study was to simulate an effective diffusion-weighted imaging (DWI) pulse sequence and to evaluate the best b value in skeletal muscle. The evaluated pulse sequences were spin echo (SE), stimulated echo (STE), and gradient-recalled echo (GRE). The signal intensity changed in some DWI pulse sequences when the b value was changed. Moreover, the static magnetic field of 1.5 T was compared with that of 3.0 T. Next, diffusion tensor imaging of the human skeletal muscle was measured. The experimental subjects were healthy male volunteers (n = 7; age 21.8 ± 1.1 years). We changed the b value in steps of 100 s/mm(2) from 0 to 2000 s/mm(2), and the diffusion values [fractional anisotropy (FA), λ(1), λ(2), and λ(3)] were calculated based on the data. The STE method could maintain signals up to b values of 1300 s/mm(2), but the SE and GRE methods suffered from high noise. In the human study, the mean FA (±SD) was 0.41 ± 0.02 in the tibialis anterior muscle (TA) and 0.31 ± 0.02 in the soleus muscle (SOL) at a b value of 1000 s/mm(2). The correlation of the FA with the b value coefficient and the P value by Student's t test were r = 0.981 and P < 0.001 for the TA and r = 0.982, P < 0.001 for the SOL. However, the FA became high with a low b value. In conclusion, STE was very useful for DWI in a short T (2)-value tissue. Moreover, a minimum b value of 800 s/mm(2) was necessary for evaluation of human skeletal muscle.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s12194-012-0174-1DOI Listing

Publication Analysis

Top Keywords

skeletal muscle
16
human skeletal
12
stimulated echo
8
pulse sequence
8
dwi pulse
8
pulse sequences
8
muscle
6
s/mm2
5
characteristics diffusion-weighted
4
diffusion-weighted stimulated
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!