Background And Objective: Spirometry is insensitive to small airway abnormalities in asthma. Our objective was to evaluate regional lung structure and function using hyperpolarized (3)He magnetic resonance imaging (MRI) before, during and after a methacholine challenge (MCh).

Methods: Twenty-five asthmatics (mean age = 34 ± 11 years) and eight healthy volunteers (HV) (mean age = 33 ± 11 years) underwent spirometry, plethysmography and hyperpolarized (3)He MRI prior to a MCh. MRI was repeated following the MCh and again 25 min after salbutamol administration. (3)He MRI gas distribution was quantified using semiautomated segmentation of the ventilation defect percent (VDP). Tissue microstructure was measured using the (3)He apparent diffusion coefficient (ADC). Analysis of variance with repeated measures was used to evaluate changes at each time point as well as to determine interactions between regions of interest (ROI) and subject group. Pearson's correlations were performed to evaluate associations between (3)He MRI measurements and established clinical measures.

Results: In asthmatics, but not HV, whole-lung ADC was increased post-MCh (P < 0.01). In asthmatics only, ADC was increased post-MCh in posterior ROI (P < 0.01) and all ROI in the superior-inferior direction (P < 0.01). VDP was increased in posterior and inferior ROI (P < 0.001). There was a correlation between VDP and specific airway resistance (r = 0.74, P < 0.0001), dyspnoea score (r = 0.66, P < 0.01) and fractional exhaled nitric oxide (r = 0.45, P < 0.05).

Conclusions: We evaluated the regional pulmonary response to methacholine and salbutamol using (3)He MRI and showed heterogeneous VDP and ADC consistent with bronchoconstriction and gas trapping, respectively, post-MCh. These regional alterations resolved post-salbutamol.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1440-1843.2012.02250.xDOI Listing

Publication Analysis

Top Keywords

3he mri
16
hyperpolarized 3he
12
regional pulmonary
8
pulmonary response
8
response methacholine
8
methacholine challenge
8
3he magnetic
8
magnetic resonance
8
resonance imaging
8
age years
8

Similar Publications

Machine Learning and CT Texture Features in Ex-smokers with no CT Evidence of Emphysema and Mildly Abnormal Diffusing Capacity.

Acad Radiol

June 2024

Robarts Research Institute, Western University, 1151 Richmond St N, London, N6A 5B7, Canada (M.S., G.P.); Department of Medical Biophysics, Western University, London, Canada (M.S., G.P.); Division of Respirology, Department of Medicine (D.G.M., G.P.); School of Biomedical Engineering, Western University, London, Canada (G.P.). Electronic address:

Rationale And Objectives: Ex-smokers without spirometry or CT evidence of chronic obstructive pulmonary disease (COPD) but with mildly abnormal diffusing capacity of the lungs for carbon monoxide (DL) are at higher risk of developing COPD. It remains difficult to make clinical management decisions for such ex-smokers without other objective assessments consistent with COPD. Hence, our objective was to develop a machine-learning and CT texture-analysis pipeline to dichotomize ex-smokers with normal and abnormal DL (DL≥75% and DL<75%).

View Article and Find Full Text PDF

The patterns of idiopathic pulmonary fibrosis (IPF) lung disease that directly correspond to elevated hyperpolarised gas diffusion-weighted (DW) MRI metrics are currently unknown. This study aims to develop a spatial co-registration framework for a voxel-wise comparison of hyperpolarised gas DW-MRI and CALIPER quantitative CT patterns. Sixteen IPF patients underwent He DW-MRI and CT at baseline, and eleven patients had a 1-year follow-up DW-MRI.

View Article and Find Full Text PDF

X-nuclear MRS and MRI on a standard clinical proton-only MRI scanner.

J Magn Reson Open

December 2023

Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, United States.

In light of the growing interest deuterium metabolic imaging, hyperpolarized C, N, He, and Xe imaging, as well as P spectroscopy and imaging in large animals on clinical MR scanners, we demonstrate the use of a (radio)frequency converter system to allow X-nuclear MR spectroscopy (MRS) and MR imaging (MRI) on standard clinical MRI scanners without multinuclear capability. This is not only an economical alternative to the multinuclear system (MNS) provided by the scanner vendors, but also overcomes the frequency bandwidth problem of some vendor-provided MNSs that prohibit users from applications with X-nuclei of low magnetogyric ratio, such as deuterium (6.536 MHz/Tesla) and N (-4.

View Article and Find Full Text PDF

Pulmonary imaging measurements using magnetic resonance imaging (MRI) and computed tomography (CT) have the potential to deepen our understanding of chronic obstructive pulmonary disease (COPD) by measuring airway and parenchymal pathologic information that cannot be provided by spirometry. Currently, MRI and CT measurements are not included in mortality risk predictions, diagnosis, or COPD staging. We evaluated baseline pulmonary function, MRI and CT measurements alongside imaging texture-features to predict 10-year all-cause mortality in ex-smokers with ( = 93; 31 females; 70 ± 9years) and without ( = 69; 29 females, 69 ± 9years) COPD.

View Article and Find Full Text PDF

The purpose of this study was to anatomically correlate ventilation defects with regions of air trapping by whole lung, lung lobe, and airway segment in the context of airway mucus plugging in asthma. A total of 34 asthmatics [13M:21F, 13 mild/moderate, median age (range) of 49.5 (36.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!