A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Small cause - big effect: improvement in interface design results in improved data quality - a multicenter crossover study. | LitMetric

In Germany the core data set for anesthesia version 3.0 was recently introduced for external quality assurance, which includes five surgical tracer procedures. We found a low rate of correctly documented tracers when compared to procedure data (OPS-Codes) documented separately. Examination revealed that the graphical user interface (GUI) contravened the dialogue principles as defined in EN ISO 9241-110. We worked with the manufacturer to implement small improvements and roll out the software. A crossover study was conducted at a university hospital and a municipal hospital chain with five hospitals. All study sites and surgical tracer procedures combined, we found an improvement from 42% to 65% (p<0.001; N=34,610) correctly documented anesthesias. We also saw improvements for most of the observed surgical tracer procedures at all hospitals. Our results show the big effect small changes to the GUI can have on data quality. They also raise the question, if highly flexible and parameterized clinical documentation systems are suited to achieve high usability. Finding the right balance between GUIs designed by usability experts and the flexibility of parameterization by administrators will be a difficult task for the future and subject to further research.

Download full-text PDF

Source

Publication Analysis

Top Keywords

crossover study
8
surgical tracer
8
tracer procedures
8
small big
4
big improvement
4
improvement interface
4
interface design
4
design improved
4
improved data
4
data quality
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!